{"product_id":"pce-128-6-ixwdometro-flow-cup-viscometer","title":"Viscometer - Flow Cup Viscometer","description":"\u003cdiv class=\"tab-pane fade in\" id=\"tab-customdata3\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003e\u003cspan\u003eTechnical specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasuring range (cSt)  \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlow time (sec.)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput nozzle Ø (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cspan\u003ePCE-128\/6 \u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e188 ... 684 cSt\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 ... 100 sec\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.0 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cspan\u003ecup: anodized aluminum\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003enozzle: stainless steel\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eStandards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eISO 2431, DIN 53224, EN 535, ASTM D5125\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cspan\u003eØ inner 50 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eØ outer 85 mm\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eheight 85 mm\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eapproximately\u003cspan\u003e \u003c\/span\u003e310 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane fade in active\"\u003e\n\u003cdiv style=\"text-align: left;\" class=\"usertext\"\u003e\n\u003cdiv align=\"center\" style=\"text-align: center;\" data-mce-style=\"text-align: center;\"\u003e\n\u003cstrong\u003eViscosity Meter \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInternational standard DIN 53224 \/ Cup made of anodized aluminum\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"center\" style=\"text-align: left;\" data-mce-style=\"text-align: left;\"\u003e\n\u003cbr\u003eFlow cup viscometers are suitable for determining the flow time of Newtonian \/ borderline Newtonian fluids according to international standards and are often used in laboratories and industrial production. For the measurement, the nozzle must be closed and the fluid to be measured must be poured into the flow cup. Placing the glass plate on top of the cup creates a vacuum that prevents the fluid from flowing and serves to position the cup on the tripod for timing. When the glass plate is then pulled away from the flow cup, the fluid flow from the nozzle starts and timing begins simultaneously. Once the flow stops, the timing must also stop. For a relative value, this method is absolutely sufficient in many fields. To ensure the accuracy of the cup, it is important to clean it thoroughly after each use. It is important to ensure that the surface inside the cup has not been damaged. Any scratches or dry material residues will affect further measurements.\u003c\/div\u003e\n\u003cbr\u003e- Highly polished and processed cup for optimal drainage\u003cbr data-mce-fragment=\"1\"\u003e- Includes factory calibration certificate\u003cbr data-mce-fragment=\"1\"\u003e- With overflow channel\u003cbr data-mce-fragment=\"1\"\u003e- Complies with international standards\u003cbr data-mce-fragment=\"1\"\u003e- Base available optionally\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\" class=\"usertext\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\" class=\"usertext\"\u003e\n\u003cstrong\u003ePackage contents\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata4\" class=\"tab-pane fade in\"\u003e\n\u003cdiv style=\"text-align: left;\" class=\"usertext\"\u003e1 x PCE-128\/6 Flow cup viscometer\u003cbr\u003e1 x Glass Plate\u003cbr\u003e1 x Industrial Calibration Certificate\u003cbr\u003e1 x User manual\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE Instruments","offers":[{"title":"Default Title","offer_id":42087440810037,"sku":"PCE-128\/6","price":259.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8396\/9077\/products\/pce-instruments-iso-flow-cup-viscometer-pce-128-6-5957398_1628865.webp?v=1674567879","url":"https:\/\/organametrisis.gr\/en\/products\/pce-128-6-ixwdometro-flow-cup-viscometer","provider":"Όργανα Μέτρησης","version":"1.0","type":"link"}