Ammeter Clamp - Multimeter
PCE-LCT 1
| Technical specifications | |||
| Current and leakage current (AC A) | |||
| Measurement range | Reading | Accuracy | |
| 50 / 60 Hz | 400 Hz ... 1 kHz | ||
| 40mA | 10 mA | ± (1 % + 0.5 mA) | ± (4.5 % + 0.5 mA) |
| 400mA | 100 mA | ± (3 % + 5 mA) | ± (3 % + 5 mA) |
| 4 A | 1 mA | ± (4 % + 0.1 mA) | ± (4 % + 0.1 A) |
| 40 A | 10mA | ± (4 % + 1 A) | ± (4 % + 1 A) |
| 80 A | 10mA | ± (2.5 % + 1 A) | ± (3 % + 1 A) |
| 80 A - 100 A | 100mA | ± (5 % + 1 A) | ± (5 % + 1 A) |
| Voltage (AC V) | |||
| Measurement range | Reading | Accuracy | |
| 50 / 60 Hz | 400 Hz ... 1 kHz | ||
| 400V | 1 V | ± (1.5 % + 2 digits) | ± (2 % + 4 digits) |
| Resistance | |||
| Measurement range | Reading | ||
| Accuracy | Alarm | ||
| 400 Ω | 0.1 Ohm | ± (1 % + 2 digits) | Measured value <38Ω |
| General Technical Specifications | |||
| Screen | 3 3/4 | ||
| Measurement parameters | AC V, AC A, resistance | ||
| Safety standards | CAT III 300 V / CAT II 600 V | ||
| Clip diameter | 30 mm | ||
| Input resistance | 10 MΩ | ||
| Storage rate | 2 Hz (numeric values), 20 Hz (bar graph) | ||
| Operating temperature | -10 ºC ... 50 ºC / 14 º F ... 122 º F | ||
| Operating humidity | <85 % Time | ||
| Storage temperature | -20 ºC ... 60 ºC / -4 º F ... 140 º F | ||
| Automatic shutdown | after 30 minutes of inactivity | ||
| Power supply | 9V battery | ||
| Input current | 10mA | ||
| Weight | 200 g / 7 oz | ||
| Dimensions | 210 x 62 x 35.6mm / 8.2 x 2.4 x 1.4in | ||
- Measures current up to 100 A
- Measures voltage up to 600 V
- Continuity test
- Measures resistance up to 400 Ω
- Digital bar graph
- High resolution
- Maximum and minimum value are displayed on the screen
- Rubber protector
- Test leads included
1 x PCE-LCT 1
1 x 9V battery
2 x Test Leads
1 x Carrying case
1 x User Manual