{"product_id":"pce-ph20-metrhths-ph-me-exwteriko-probe","title":"pH Meter with External Probe","description":"\u003cdiv id=\"tab-customdata3\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eMeasuring range\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e0.00 ... 14.00 pH\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eResolution\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e0.01 pH\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eAccuracy\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eplus-minus 0.07 pH (in the range 5 ... 9 pH) \u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e plus-minus 0.1 pH (in the range 4 ... 4.9 and 9.1 ... 10 pH) \u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e plus-minus 0.2 pH (in the range 1. .. 3.9 and 10 ... 13 pH)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eCalibration\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eAutomatically, at pH 4, 7, or 10 using calibration solutions\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eElectrode\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003epH electrode with BNC connector for liquids\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003ePower supply\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e4 x 1.5V AAA batteries\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eEnvironmental conditions   \u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e0 ... 60degreesC \/ 32 ... 140degreesF, \u003c80% rh\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003eDimensions\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e180 x 40 mm \/ 7 x 1.6 in\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e\u003cspan style=\"vertical-align: inherit;\"\u003e220 g \/ \u003c 1 lb\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"usertext\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"usertext\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-center\"\u003e\n\u003ch2\u003ePCE-PH20 easy-to-use pH meter for pH determination\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExternal pH electrode \/ Recalibratable \/ Waterproof (IP 67)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-justify\"\u003e\n\u003cp\u003eThe pH meter was developed to directly determine the pH in aqueous media or water-based solutions. The waterproof pH tester PCE-PH20 is used for fast and accurate measurement of pH. The practical display makes the pH value on the pH meter easy to read. Due to the waterproof and robust housing (IP 67), the pH value tester can also be used under difficult conditions. A recalibration always guarantees optimum accuracy and is very easy to perform using the optionally available calibration kits (automatic calibration function without calibration screws—performed only via the keyboard).\u003c\/p\u003e\n\u003cp\u003eWater quality in aquariums is extremely important for the living organisms that inhabit it. Slight changes in pH level and temperature may lead to aggravating results and even death of the fish or reptiles in the water tank. Therefore, the application of the appropriate pH meter is required.\u003cimg class=\"img-responsive img-right\" alt=\"PH Meter PCE-PH20 for checking aquarium quality.\" src=\"\/english\/g\/custom\/product-pictures\/ph-meter-pce-ph20-application-aquaristic.jpg\"\u003e The aquarium ecosystem must be as similar to natural conditions as possible. Therefore, measurements should be regular and provide accurate results.\u003c\/p\u003e\n\u003cp\u003eDepending on the purpose of creating an aquarium—commercial, scientific (experimental and laboratory tests), decorative—the most desirable pH level should be maintained to provide correct living conditions for the fish and other possible organisms there. Modern devices are often portable and easy-to-use instruments which help to monitor changes in the pH level during the day or from day to day, etc. The glass electrodes have a long service life and due to a high level of precision and wide measurement range, it is possible to use the meter often and detect the slightest deviations. For this type of measurement, the presence of a temperature sensor is very important, since temperature changes may occur within one aquarium and should be detected immediately.\u003c\/p\u003e\n\u003cp\u003eRegardless of its purpose, the aquarium's main task is to create the best conditions and the most favorable environment. This task can be more challenging than it seems, because simply filling the tank with fresh water is not enough; much depends on the water's parameters and how they may change over time.\u003cimg class=\"img-responsive img-left\" alt=\"Aquarium pH Meter PCE-PH20 shows pH 8.01.\" src=\"\/english\/g\/custom\/product-pictures\/aquarium-ph-meter-pce-ph20-application.jpg\"\u003e Depending on the fish type, there may be slightly different requirements for the pH level of water (from 6 to 8 on average, but there may be exceptions). A very influential factor is also the type of water the owner decides to choose for the aquarium. Fresh and saltwater have different desirable pH levels and it is important to take this into consideration. As a rule, saltwater has a higher pH value than freshwater (8 and above). Before choosing the inhabitants for the aquarium, it is necessary to learn more about their natural habitat, because the conditions in the aquarium should be maximally adjusted to the natural ones. The pH level in the aquarium should be maintained at the desirable level. The rise of pH may have a destructive influence, since the increasing ammonia deteriorates the water quality and may be very harmful to the fish. That is why pH level control in the aquarium is practically a daily task if your intention is to have a beautiful water tank with healthy inhabitants.\u003c\/p\u003e\n\u003cp\u003eFishes are very sensitive to fluctuations in pH, especially if the values differ significantly from their natural and usual levels. The pH tester allows the user to check the current pH level within just a few seconds and make immediate adjustments if deviations occur.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata4\" class=\"tab-pane clear fade in\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x pH meter PCE-PH20 \u003cbr\u003e1 x pH electrode PE-03 \u003cbr\u003e4 x Battery \u003cbr\u003e1 x Calibration kit with solutions pH4 + 7 (each 75 ml vial) \u003cbr\u003e1 x Operating instructions \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE Instruments","offers":[{"title":"Default Title","offer_id":48146740216131,"sku":"PCE-PH20","price":167.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0572\/8396\/9077\/files\/pce-instruments-aquarium-ph-meter-pce-ph20-5856134_1124923.webp?v=1712135659","url":"https:\/\/organametrisis.gr\/en\/products\/pce-ph20-metrhths-ph-me-exwteriko-probe","provider":"Όργανα Μέτρησης","version":"1.0","type":"link"}