PCE-RT 2300 - Portable roughness tester
Κωδικός | Τιμή ** | Στοκ | |
---|---|---|---|
PCE-RT 2300 | €2.512,00 | 2-5 εργάσιμες |
Measurement range |
Rz: 0.02 µm ... 320 µm; Ra, Rq: 0.005μm ... 32μm, Rz = 320μm (-160μm~160μm) / 12600μin (-6300μin~+6300μin) |
Accuracy | ± 10% |
Repeatability | ± 6% |
Reading |
± 20 µm: 0.01 µm ± 40 µm: 0.02 µm ± 80 µm: 0.04 µm |
Measurement Parameters | Ra, Rz, Rq, Rt, Rc, Rp, Rv, R3z, R3y, Rz (JIS), Ry, Rs, Rsk, Rku, Rmax, Rsm, Rmr, RPc, Rk, Rpk, Rvk, Mr1, Mr2 |
Measurement Standards | ISO4287, ANSI b46.1, DIN4768, JISb601 |
Graphic illustration |
Main Profile (Roughness + Waveform) Roughness profile (roughness) Loading curves |
Measurement filter | RC, PC-RC, Gauss, DP |
Cut-off length | 0.25mm, 0.8mm, 2.5mm |
Measurement length |
1 ... 5* measurement path Maximum 17.5mm (including pre- and post-run) |
Sensor |
Diamond tip, 90° angle 5 µm |
Sensor power | <4 mN |
Scan speed |
0.25 mm for cut-off 0.135 mm / s 0.8 mm for a cut-off of 0.5 mm / s 2.5 mm for a cut-off of 1 mm / s |
Screen | 3.5" LCD |
Power supply |
3.7 V Li-ion battery 5 V / 800mA Adapter USB power |
Operating time | 50 h |
Operating conditions | -20 ... 40°C / -4 ... 104°F, maximum 90% rh |
Storage conditions | -40 ... 60°C / -40 ... 140°F, maximum 90% rh |
Dimensions |
Main unit: 158 x 55 x 52 mm / 6.2 x 2.2 x 2 in motor unit: 115 x 23 x 27 mm / 4.5 x 1 x 1.1 in |
Weight | About 500g / 1.1lb |
Portable meter for direct detection of roughness (Ra, Rz, Rq, Rt and more) / Detachable sensor unit / Touch screen / Range 320μm or 12.6mil
The PCE-RT 2300 is ideal for measuring surface roughness. The meter has a detachable motorized sensor, which makes it possible to determine the roughness even on small or narrow profiles. The measured values are displayed on the meter's large LCD screen. The device is powered by a battery or via a USB cable with power.
The detachable motorized sensor is connected by cable to the meter main unit. The diamond stylus is installed on the sensor, which presses with a maximum force of 4 mN on the surface to be measured. The roughness meter measures according to applicable ISO, ANSI and JIS standards.
Below is an interpretation of the main results that the PCE-RT 2000 gives after the measurement:
Rz = average roughness depth
The average roughness Rz is the arithmetic average of the largest degrees of roughness of several adjacent individual measuring sections.
Ra = number average roughness
Ra is the generally recognized and internationally applied roughness parameter. It is the arithmetic mean of the absolute values of the deviations of the profile from the reference line. The measured Ra value is always less than the Rz value determined on the same roughness profile.
Rt = maximum surface roughness
The maximum surface roughness Rt is the distance between the highest and lowest point of the measuring section.
Rq = root mean square roughness
Rq is the root mean square of all axial measurements (coordinates) within the defined measurement distance l. Rq corresponds to the name RMS (Root Mean Square).
Characteristics :
- Touch screen
- Measurement of all roughness values
- Battery and mains operation
- Adjustable different filters
- Diamond head
- Detachable motorized sensor
Package contents
1 x PCE-RT 2300 roughness meter
1 x small sensor
1 x detachable motorized sensor
2 x connection cables for the motor unit
1 x charger
1 x interface cable
1 x carrying case
1 x User Manual