PCE-TDS 100HS - Ultrasonic Flowmeter Ø20-108mm
Κωδικός | Διάμετρος Σωλήνα | Τιμή | Στοκ | ||
---|---|---|---|---|---|
PCE-TDS 100HS | Ø20-108 mm | €1.590,00 | 2-5 εργάσιμες | ||
PCE-TDS 100H | Ø57-720 mm | €1.590,00 | Με παραγγελία | ||
PCE-TDS 100HSH | Ø20-720 mm | €1.924,00 | Με παραγγελία |
Measurement range | -32 ... 32 m/s, -105 ... 105 ft/s |
Reading | 0.0001 m/s, 0.00033 ft/s |
Accuracy for DN ≥ 50 mm: for DN < 50 mm: |
± 1.5% of the measured value ± 3.5% of the measured value |
Reproducibility | ± 1.0% of measured value |
Means of measurement |
All fluids with impurity <5% and flow >0.03 m³/h |
Flow units |
Cubic meter [m³] |
Time settings |
Per day [/d] |
Memory | 60,000 measurements |
Exit | USB (for online measurement and reading of the internal memory) |
Sealing class | IP 52 |
Power supply |
3 x rechargeable batteries AA NiMH / 2100 mAh (with a full charge 12 hours of operation) 100 … 240 V AC 50/60 Hz |
Dimensions | 214 x 104 x 40 mm / 8.4 x 4.1 x 1.5 in |
Weight | 450 g / 15 oz |
Sensor (PCE-TDS 100 HS only) | Nominal width DN 15 … 100, 20 … 108 mm / approx 3/4 ... 4" |
Liquid temperature | -30 ... 160°C / -22 ... 320°F |
Dimensions | 45 x 30 x 30 mm / 1.7 x 1.1 x 1.1 in |
Weight | 75 g / < 1 lb |
PCE-TDS 100HS Ultrasonic Flowmeter
Measures liquid flow velocity in pipes with a diameter of 20 ... 108 mm / ≈ 3/4 ... 4 in
The flow rate calculation according to the transit time principle is as follows:
v = measured velocity
T1 = execution time of the ultrasonic signal in the flow direction
T2 = time of execution of the ultrasonic signal against the direction of flow
L = length of the ultrasonic wave
α = angle of ultrasonic signal to the flow
The principle of transit time requires that the tubes are full and free of bubbles and particles.
Note: To transfer data to a PC, SOFT-PCE-TDS software is required. Software sold separately.
The user must take into account that the measured values of the meter depend on the geometry, material and coating of the pipe, the type of medium, its temperature and its velocity, the type of sensor and the method of measurement.
- Installation without interrupting the process
- Easy assembly
- Accurate and reliable
- No pressure loss
- Maintenance free, no moving parts
- No wear and tear
- Portable devices for control measurements
Package contents
2 x TDS-S1 sensor (PCE-TDS 100HS)
2 x 5 m / 16.4 ft connection cables
2 x Velcro straps
1 x Transformer
1 x Contact Gel
1 x Plastic case
1 x User Manual