Αισθητήρας με μαγνητική βάση για ρόομετρα υπερήχων Ø 57-720 mm

Κωδικός Τιμή Στοκ
PCE-TDS 200 MR SENSOR €779,00 Με παραγγελία


Τιμές χωρίς ΦΠΑ 24%
   
Flow measurement  
Measuring range plus-minus32 m/s
Accuracy 0,001 m/s
Genauigkeit DN greater than or equal to50 mm: plus-minus1.5 % f.s. for velocities > 0.3 m/s
  DN <50 mm: plus-minus3.5 % f.s. for velocities > 0.3 m/s
Reproducibility plus-minus0.5 % of measured value
   
PCE-TDS 200 MR SENSOR Sensor pair
Pipe diameter DN 50 ... 700 / 57 ... 720 mm
Temperature resistance -30 ... 160 degreesC
Dimension -30 ... 160 degreesC
 
Measuring method Z, V, N, W
Medium - water
  - sea water
- oil
  - crude oil
  - methanol
  - ethanol
  - diesel
  - petrol
  - petroleum
  - user defined
  (manual input of the sound velocity from the medium)
   
All liquids with an impurity <5 %
Pipe material - copper CU
  - steel FE
  - stainless steel VA
  - aluminium AL
  - brass ME
  - cast iron CI
  - iron FE
  - nickel NI
  - titanium TI
  - zink ZI
- acrylic AC
  - polyethylene PE
  - polypropylene PP
  - polyvinyl chloride PVC
  - nylon NY
  - user defined
(manual input of the transversal sound velocity
  of the pipe material)
   
Inner pipe lining - no lining
  - user defined
  - epoxy resin
  - rubber
  - mortar
  - polystyrene PS
  - polyethylene PE
  - polytetrafluoroethylene PTFE
- polyurethane PU
  - polypropylene PP
  - user defined
  (manual input of the longitudinal sound velocity
  of the inner lining of the pipe)
   
Measurement parameters flow velocity, volume flow and volume
Units (dimensions) mm, in
Units (flow velocity) m/s, ft/s
Units (volume flow) m³, l, gal, igl, mgl, cf, bal, ib, ob
Time specification seconds, minutes, hours, days
Units (volume) m³, l, gal, igl, mgl, cf, bal, ib, ob
   
Temperature measurement  
Measuring range Accuracy
Type B: 600 ... 1800 degreesC Type B: plus-minus(0.5 % + 3 degreesC)
Type E: -100 ... +900 degreesC Type E: plus-minus(0.4 % + 1 degreesC)
Type J: -100 ... 1150 degreesC Type J: plus-minus(0.4 % + 1 degreesC)
Type K: -100 ... +1370 degreesC Type K: plus-minus(0.4 % + 1 degreesC)
Type N: -100 ... + 1150 degreesC Type N: plus-minus(0.4 % + 1 degreesC)
Type R: 0 ... 1700 degreesC Type R: plus-minus(0.5 % + 3 degreesC)
Type S: 0 ... 1500 degreesC Type S: plus-minus(0.5 % + 3 degreesC)
Type T: -100 ... +400 degreesC Type T: plus-minus(0.4 % + 1 degreesC)
   
Resolution  0.1 degreesC
Connectable thermocouples B, E ,J ,K ,N ,R ,S ,T
Measuring parameters flow rate, volume flow, volume, temperature,
  Heat output and heat quantity
Units (temperature)  degreesC / degreesF
Units (heat quantity) K, kJ, MJ, Wh, kWh, MWh, Btu, kBtu, MBtu
Units (heat output) W, kW, MW, J/h, kJ/h MJ/h, Btu/h, kBtu/h, MBtu/h
Cost display EUR, Pound, USD, Turkish Lira, Zloty, Yen

Further specifications
2.8" LCD 2,8“ LCD
Menu metrisch / imperial
Menu languages German, English, French, Spanish,
  Italian, Dutch, Portuguese, Danish, Turkish, Polish, German
  Turkish, Polish, Russian, Chinese, Japanese
Operating and storage conditions  Temperature: -20 ... +65 degreesC
  Humidity: 10 ... 95 % r. h., non-condensing
Data logger 32 GB memory capacity / 10 million measuring points
 Unterface USB (for online measurement, readout of the internal memory
  memory and for recharging the battery)
Protection class IP52
Power supply Internal Internal: LiPo battery (3.7 V, 2500 mAh)
  External: USB 5 VDC, 500 mA
Operating time approx. 10 h
Dimensions 165 x 85 x 32 mm
Weight 255 g
   

Ultrasonic flowmeter with 32 GB data memory / measuring range ±32 m/s / 
reproducibility ±0.5 % of measured value / different measuring probes / alarm limit values /
2.8 " LC display / for all media / optionally with DAkkS or ISO calibration certificate

The ultrasonic flowmeter has a measuring range of ±32 m/s. With an accuracy of ±1.5 % f.s. for a pipe diameter of DN ≥50, ±3.5 % f.s. for a pipe diameter of DN <50 and a reproducibility of ±0.5 % f.s., the ultrasonic flow meter is a particularly precise measuring device. An installation aid is available for installing the sensors of the ultrasonic flow meter. The installation aid graphically displays the signal quality of the ultrasonic flow meter. In addition, it is graphically displayed whether the sensors of the ultrasonic flow meter are positioned at the correct distance from each other. To carry out flow measurements with the ultrasonic flow meter, the flow velocity, the volume flow and the volume are displayed after entering the pipe and medium specifications. The ultrasonic flow meter displays the measured values in a wide range of units. For example: m³, l, gal, igl, mgl, cf, bal, ib and ob. 

During a measurement, it is possible to record the measured values via the data logger function of the ultrasonic flow meter. Start and stop conditions and the storage interval can be set from 1 second to 12 hours for the ultrasonic flow meter. A memory point of the ultrasonic flow meter contains all measured values once. The measured values are stored on the 32 GB built-in memory of the ultrasonic flow meter. 10 million measuring points can be stored on the ultrasonic flow meter.

With the optional software, the recorded measured values can be read out from the ultrasonic flow meter. For analysis, the measured values from the ultrasonic flow meter can be displayed in tabular and graphic form. For further processing of the measured values from the ultrasonic flow meter, they can be exported in .csv file format. Alternatively, a PDF report can be created via the software. For simplified operation, the ultrasonic flow meter can be set via the software. A live view of the measured values from the ultrasonic flow meter is also possible with the software. 

In order to determine the amount of heat with the ultrasonic flow meter, two additional thermocouples are required. These are available with the PCE-TDS 200+. The two thermocouples of the ultrasonic flow meter are connected to the flow and return of a pipe system. Based on the temperature difference and the measured flow rate, the ultrasonic flow meter can determine the amount of heat. If required, the ultrasonic flow meter can calculate and display the costs per unit of heat simultaneously during the measurement. Thus, the ultrasonic flow meter is used, for example, in the inspection of heating systems.

The LC colour display of the ultrasonic flow meter has a size of 2.8" and is therefore easy to read. Optionally, the ultrasonic flow meter can be equipped with an ISO or DAkkS calibration certificate. 

PCE-TDS 200 MR SENSOR
Separate on-rail sensors for pipe sizes DN 50 ... 700 / 57 ... 720 mm. The temperature resistance is between -30 ... 160 °C. The sensor on the respective rail is located on a rail and can therefore be positioned appropriately. Magnets are located underneath the rails which make it possible to hold on to pipes with a ferrous metal by themselves.

- Measuring range ±32 m/s
- USB-C interface for data transfer 
- Optional software for analysing the measured values
- Reproducibility ±0.5 % of measured value 
- Heat quantity measurement
- Data memory for 10 million measuring points
- individually adjustable alarm limits
- optionally with ISO or DAkkS calibration certificate

1 x Ultrasonic flow meter PCE-TDS 200 MR
1 x Flow sensor PCE-TDS 200 MR SENSOR (pair)
2 x 5 m connection cable 
2 x detachable cable ties
1 x power supply unit
1 x USB-C cable
1 x ultrasonic contact gel 
1 x PCE measuring tape
1 x plastic case
1 x instruction manual