PCE-TG 150 HT - Ultrasonic Thickness Gauge 1.2-300 mm with 5MHz frequency for high temperatures 350°C
Measurement range | 1.20 ... 300.0 mm / 0.04 ... 11.81" | |
Reading | 0.01mm to ≤99.99mm | |
0.1mm to ≥100.0mm | ||
Accuracy | ±0.5 % of the measured value + 0.05 mm | |
Memory | 1500 measured values | |
Detector frequency | 5 MHz | |
Standard sensor | PCE-TG HT | |
Temperature range | -10 ... 350ºC / 14 ... 662ºF | |
Diameter |
|
|
Further specifications | ||
Adjustable audio speed |
1000 ... 9999 m/s | |
Minimum pipe diameter | Ø20 x 3 mm (steel) | |
Materials library | 15 memory locations | |
Calibration standard | 4 mm | |
Screen | Color TFT LCD 2.4 in | |
with brightness adjustment | ||
Power supply | 3 x 1.5V AA batteries | |
Automatic shutdown | off, 2, 5, 10, 30 minutes | |
Environmental conditions | 0 ... 40 °C / 32 ... 104 °F, <90 % RH, non-condensing | |
Dimensions | 163 x 82 x 38mm / 6.4 x 3.2 x 1.5" | |
Weight | 320g / 11.2oz |
Caliper with data memory / Adjustable sound speed /
Casing-mounted calibration standard / Measurement of material thickness up to 300 mm /
Limit alarm
Casing-mounted calibration standard / Measurement of material thickness up to 300 mm /
Limit alarm
The ultrasonic caliper can measure material thickness up to 300mm / 11.81". In order to be able to measure the material thickness of a wide variety of homogeneous materials, it is possible to store the corresponding sound speed in the caliper, as the caliper has a material library and for materials such as steel, aluminum, zinc, silver and gold, the appropriate sound speeds are already stored.
With the limit value function, individual maximum and minimum values can be stored, so that when the measured value of the sample is outside these limits, the caliper displays a corresponding indication on the screen as well as an audible alarm.
The caliper has a data memory in which the measured values can be stored. The stored data is displayed graphically on the screen as well as the maximum, minimum and average value of the measurements.
With the limit value function, individual maximum and minimum values can be stored, so that when the measured value of the sample is outside these limits, the caliper displays a corresponding indication on the screen as well as an audible alarm.
The caliper has a data memory in which the measured values can be stored. The stored data is displayed graphically on the screen as well as the maximum, minimum and average value of the measurements.
- Measured value memory
- Calibration reference on housing
- Auto power off
- Measure material thickness up to 300mm / 11.81"
- Battery status indicator
Package contents
1 x PCE-TG 150 HT Ultrasonic Thickness Gauge
1 x Sensor PCE-TG HT
1 x Gel (TT-GEL)
1 x Carrying bag
3 x 1.5V AA batteries
1 x User Manual
1 x Sensor PCE-TG HT
1 x Gel (TT-GEL)
1 x Carrying bag
3 x 1.5V AA batteries
1 x User Manual