The measuring rules based on the DIN 866 standard are high-precision measuring tools, made of stainless steel or other stable material, suitable for industrial and laboratory applications. This specification ensures straightness and graduation accuracy, ensuring reliable and accurate length measurements.
These rules are an essential tool in metallurgy, mechanical engineering, and in fields where accuracy is critical.
Straightness refers to the lower measuring surface.

Form A – Measuring rule with 10 mm protective ends on both sides. Form B – The measuring rule starts from 0 on the left and has a 10 mm protective end on the right.
| Length a = mm | Form A Straightness (μm) | Form A Graduation accuracy (μm) | Form B Straightness (μm) | Form B Graduation accuracy (μm) |
|---|---|---|---|---|
| 500 | 35 | 30 | 70 | 75 |
| 1000 | 60 | 40 | 120 | 100 |
| 1500 | 85 | 50 | 170 | 125 |
| 2000 | 110 | 60 | 220 | 150 |
| 3000 | 160 | 80 | 320 |