Ampere clamp - Multimeter
PCE-DC2
| Alternating current (50/60 Hz, TRMS) | |
| Measuring range | 0 ... 200.0 A |
| Reading | 0.1 A |
| Accuracy | ±(2.5% + 8 digits) |
| Direct current | |
| Measuring range | 0 ... 200.0 A |
| Reading | 0.1 A |
| Accuracy | ±(2.0% + 5 digits) |
| DC voltage | |
| Measuring range | 0 ... 600.0 V |
| Reading | 0.1 V |
| Accuracy | ±(1.0% + 2 digits) |
| AC voltage (50/60 Hz, TRMS) | |
| Measuring range | 0 ... 600.0 V |
| Reading | 0.1 V |
| Accuracy | ±(1.5% + 8 digits) |
| Resistance | |
| Measuring range | 0 ... 999.9 Ω |
| Reading | 0.1 Ω |
| Accuracy | ±(1.5% + 8 digits) |
| Further specifications | |
|
Current clamp opening |
18 mm / 0.7" |
| Continuity test | <30Ω, test current <0.5 mA |
| Battery indication | "BAT" low battery indication. |
| Exceeding the measurement range | "OL" indication when measurement range is exceeded |
| Measurement rate | 10 Hz for the reading |
| 40 Hz for the bar graph in DC, | |
| DC voltage and resistance measurement | |
| Input resistance | 1.0 MΩ during voltage measurement |
| Display | LC with backlight |
| Response time of maximum measurement (PEAK HOLD) | <10 ms |
| Response time of the maximum and the | <50 ms |
| minimum measurement value (MAX / MIN HOLD) | |
| Operating conditions | -10 ... 50 °C / 14 ... 122 °F, maximum 3000 m / 9842 ft above sea level |
| Storage conditions | -30 ... 60 °C / -14 ... 140 °F, maximum 10,000 m / 32,808 ft above sea level |
| Ambient humidity | Maximum 90% (0 ... 30 °C / 32 ... 86 °F) |
| (RH, without condensation) | Maximum 75% (30 ... 40 °C / 86 ... 104 °F) |
| Maximum 45% (40 ... 50 °C / 104 ... 122 °F) | |
| Power supply | 2 x 1.5 V AAA batteries |
| Automatic power off | after 10 minutes of inactivity |
| Pollution degree | 2 |
| Standards | CAT III 600 V, CAT IV 300 V |
| Dimensions | 164 x 65 x 32 mm / 6.45 x 2.56 x 1.26" |
| Weight | 175 g / 6.17 oz |
The PCE-DC2 is designed to indirectly detect AC/DC current and Ohms. The clamp meter has built-in white LEDs to illuminate the measurement point and a non-contact voltage test function. The compact design of this device allows measurements to be taken in areas with limited access. The backlit display ensures clear readings even in low-light areas such as electrical cabinets or wiring ducts. The non-contact voltage test function not only supports the detection of dangerous voltage potentials but also provides you with an accurate tool for identifying cable break points in cable reels, extension cords, and device connection cables.
- LCD with 3 2/3 digits, backlight, clamp for direct current
- Measurement of AC/DC current, AC voltage, and ohms
- Memory function, zero reset for the DCA, non-contact voltage detection
- Measurement point illumination
- Automatic range selection
- Automatic shutdown
- Clamp opening: 18 mm / 0.7 in
Package contents
1 x PCE-DC2 Clamp Meter
2 x Measuring cables
1 x Carrying case
2 x Batteries
1 x User manual