51 από 51 productsGas Detector
Detect combustible gas (EX, including CH₄, C₂H₆, H₂, etc), O₂, CO or H₂S by default, support more than 30 types of gas sensors, customization for ...
View full detailsMulti-gas detector for: Flammable gases - Oxygen - Carbon monoxide - Hydrogen sulfide
Detect combustible gas (EX, including CH4, C2H6, H2, etc), oxygen (O2), carbon monoxide (CO) and hydrogen sulfide (H2S) by default, optional confi...
View full detailsMulti-Gas Detector
Detectable gases Acetaldehyde Ammonia Benzene Ethane Ethanol Ethylene Formaldehyde Hexane Isobutane Me...
View full detailsGas Detector - for flammable fuel gases
Measuring range At low concentration 0 ... 1000 ppm (methane only) At high concentration 0 ... 10000 ppm Acoustic alarm Intensity: 85 dB ...
View full detailsHydrogen Detector
High sensitivity >2 g (0.07 oz) / year Medium sensitivity >15 g (0.53 oz) / year Low sensitivity >30 g (1.05 oz) / year Sensitivity refe...
View full detailsRefrigerant Leak Detector R22, R134a, R410A, R407C
Sensitivity Adjustable high / low (per SAE J1627 evaluation criteria):6 g/year or 30 g/year for R-22 and R-134a8 g/year or 40 g/year for...
View full detailsCO2 Gas Detector
Sensor unit CO2 measurement range 0 ... 50,000 ppm (5%) (vol.) NDIR sensor Temperature (gas / ambient) 0 ... +45 °C / +32 ... +113 ºF...
View full detailsCO2 - O2 Gas Detector
Measurement operation CO2 Measuring range 0 .... 50000 ppm Reading >10001 ppm: 100 ppm Accuracy ± 100 ppm / 5% of the measured va...
View full detailsCO2 Gas Detector
Measurement range CO2 400 ... 5000 ppm Reading 1 ppm Accuracy ± (5% + 50 ppm) between 400 ... 2000 ppm and atmospheric pressure 1 ...
View full detailsDatalogger CO2 - Humidity - Temperature Recorder
CO2 measurement Measuring range 0 ... 4000 ppm Reading 1 ppm Accuracy ± 70 ppm ( ± 5% of reading ( ± 250 ppm (> 3000 ppm) A...
View full detailsCO2 Gas Detector
PM2.5 measurement function Measuring range 0 ... 250 μm / m³ Reading 1 μm / m³ Accuracy ± (10% of the rdg. + 15 μm) Humidity ...
View full detailsCO2 Detector - Thermometer - Hygrometer
Measured variable CO2 Measurement range 400 ... 5000 ppm Accuracy ± 75 ppm or ±5% of the measured value (whichever is greater) Reading...
View full detailsCO2 Detector - Hygrometer - Thermometer - Wall-mounted
Carbon dioxide CO2 Measurement range 0 ... 9999 ppm Accuracy ± 75 ppm or ±5 % of the measured value (whichever is greater) Reading ...
View full detailsCarbon Dioxide and Carbon Monoxide Detector (CO²) (CO) - Thermometer - Hygrometer
Carbon monoxide (CO) Measurement range* 0 … 1000 ppm Reading 1 ppm Accuracy ±5 % of the measuring range *CO measurement refer...
View full detailsOxygen Detector
Oxygen in liquids Measuring range 0 ... 20 mg / L Resolution 0.1 mg / L Accuracy plus-minus 0.4 mg / L Oxygen in the air (refer...
View full detailsDust Meter PM 1 / PM 2.5 / PM 10, Formaldehyde HCHO, Volatile Organic Compounds TVOC
Measuring range PM 1.0 0 ... 999 μg / m³ Accuracy ± 15% Sensor technology Laser scattering Measuring range PM 2.5 0 ... 999 μg...
View full detailsDust Meter - HCHO (Formaldehyde) - Air Quality - PM2.5 / PM10 - Datalogger - SD Card
Measurable particle sizes PM 2.5 and PM 10 Measurement range 0 ... 2000 µg / m³ Reading 1 μg / m³ Particle counter Measurable ...
View full detailsDust Meter - Air Quality - PM2.5 / PM10 Formaldehyde CO2 - Datalogger
Dust measurement PM2.5 / PM10 Measuring range 0 ... 2000 µg/m³ Reading 1 μg/m³ Measurement CO2 Measuring range 0 ... 9999 ppm ...
View full detailsDust Meter - Air Quality - PM2.5 / PM10 - Alarm - TVOC - Formaldehyde - Datalogger
Fine dust measurement PM2.5 / PM10 Measuring range 0 ... 2000 μg / m³ Reading 1 μg / m³ TVOC measurement range(volatile organic compo...
View full detailsCO2 Detector
Specification Technical specifications (12 gases choice) Typical measurement ranges and alarm adjustments Parameter/Gas Symbol Range A...
View full detailsDust Meter - Air Quality - PM1 / PM 2.5 / PM 10 - TVOC - CO2
TVOC measurement function Measuring range 0.000 ... 9.999 mg / m³ Reading 0.001 mg / m³ Accuracy ± 10% of the measured value PM1,...
View full detailsDust Meter - PM2.5
PM2.5 measurement range 0 ... 500 μg / m³ Reading 1 μg / m³ Accuracy >400 μg / m³: ± (10 μg / m³ + 50 digits) Temperature m...
View full detailsDust Meter - Air Quality - PM 2.5 / PM 10 - Datalogger
General device specifications Display 2" color LCD screen Screen resolution 220 x 176 pixel Power supply Rechargeable battery or USB p...
View full detailsDust Meter - Air Quality - PM2.5 / PM10 - Datalogger - SD Card
Mass concentration Measurable particle sizes PM2.5 / PM10 Measuring range mass concentration 0 ... 2000 μg / m³ Resolution 1 μg / m...
View full detailsDust Meter - PM 2.5 / PM 10
General device specifications Display 2.4" color LCD Screen resolution 240 x 320 pixels Power supply Built-in 1000 mAh rechargeable b...
View full detailsDust Meter - Air Quality - PM0.3 / PM0.5 / PM1 / PM 2.5 / PM5 / PM 10 - Datalogger - SD Card
General Features Environmental conditions 0 ... +50 °C / +32 ... +122 °F, 10 ... 90 % RH (non-condensing) Display Color, backlit 2.8" LCD...
View full detailsDust Meter - Air Quality - PM0.3 / PM0.5 / PM1 / PM 2.5 / PM5 / PM 10 - Datalogger - SD Card - Built-in Camera
Particle specifications Particle channels PM 2.5 / PM 10 Particle concentrations 0 ... 2000 μg / m³ Reading 1 μg / m³ Particle...
View full detailsDust Meter 0.5-25 μm - Datalogger - Factory calibrated at 0.5, 1.0, 5.0 μm variable binning
Measuring range 0.5 ... 25 μm Measurable particle sizes Factory calibrated PM0.5, PM1.0, PM5.0 Measurement efficiency 50% at 0.3 μm 100%...
View full detailsDust Meter 0.3-25μm - Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm variable binning
Measuring range 0.3 ... 25 μm Channel size measurement Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm Measurement efficiency 50% a...
View full detailsDust Meter 0.3-25 μm - Datalogger - Factory calibrated at 0.3, 0.5, 5.0 μm variable binning
Specification Measuring range 0.3 ... 25 μm Measuring channel sizes Factory calibrated at 0.3, 0.5, 5.0 μm Counting efficiency 50% at 0....
View full detailsDust Meter 0.3-25 μm - Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm variable binning
Specification Measuring range 0.3 ... 25 μm Measuring channel sizes Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm Counting effic...
View full detailsDust Meter 0.5-25 μm - Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm variable binning
Specification Measuring range 0.5 ... 25 μm Measuring channel sizes Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm Counting effic...
View full detailsDust Meter 0.5-25 μm Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm
Specification Measuring range 0.5 ... 25 μm Measuring channel sizes Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm Counting effi...
View full detailsDust Meter 0.3-25 μm Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm
Specification Measuring range 0.3 ... 25 μm Measuring channel sizes Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm Counting effi...
View full detailsDust Meter 0.3-25 μm Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Specification Measuring range 0.3 ... 25 μm Measuring channel sizes Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm Counting eff...
View full detailsDust Meter 0.5-25 μm Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm
Specification Measuring range 0.5 ... 25 μm Measuring channel sizes Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm Counting effic...
View full detailsDust Meter 0.5-25 μm Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm
Specification Measuring range 0.5 ... 25 μm Measuring channel sizes Factory calibrated at 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 μm Counting effic...
View full detailsDust Meter 0.5-75 μm Factory calibrated at 0.5, 1.0, 2.5, 5.0, 10.0, 30.0 μm
Specification Measuring range 0.5 ... 75 μm Measuring channel sizes Factory calibrated at 0.5, 1.0, 2.5, 5.0, 10.0, 30.0 μm Counting eff...
View full detailsDust Meter 0.3-25 μm factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Specification PCE-PQC 34EU Measuring range 0.3 ... 25 microm Measuring channel sizes factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0...
View full detailsDust Meter 0.3-25 μm Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Specification Measuring range 0.3 ... 25 μm Measuring channel sizes Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm Counting...
View full detailsDust Meter 0.3-25 μm Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Specification Measuring range 0.3 ... 25 μm Measuring channel sizes Factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm Counting...
View full detailsDust Meter 0.3-25 μm factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm
Specification PCE-PQC 35EU Measuring range 0.3 ... 25 microm Measuring channel sizes factory calibrated at 0.3, 0.5, 1.0, 3.0, 5.0, 10.0...
View full detailsDust Meter - Air Quality - PM2.5 / PM10 - Datalogger - USB
Specification Mass concentration Measurable particle sizes PM2.5 / PM10 Measuring range PM 2.5 0 ... 1000 microg/m³ Resolution 1 micro...
View full detailsAir Quality Meter for Microbiological Contamination ISO 14698-1 (Hospitals - Laboratories etc.)
Specification Number of micropores in the collecting head 589 Hole diameter of the micropores 0.8 mm / 0.03" Battery 6400 mA Sample...
View full detailsDust Meter - PM 2.5 / PM 10 - Datalogger - USB
Specification Mass concentration Measurable particle sizes PM2.5 / PM10 Measuring range PM 2.5 0 ... 1000 microg/m³ Resolution 1 micro...
View full detailsDust Meter - Air Quality
Technical Specifications Sampling flow rate: 2.83L/min (0.1ft³), accuracy ±5% Particle diameters: 0.3μm, 0.5μm, 1μm, 3μm, 5μm, 10μm (simultaneo...
View full detailsVolatile Organic Compounds (VOC) and Formaldehyde (HCHO) Detector
HCHO Measuring range 0.00... 5.00 ppm or mg/m³ Reading 0.01 ppm or mg/m³ Accuracy ± 5% of the measured value TVOC Measu...
View full detailsUltrasonic Gas Leak Detector
Measurement start Ultrasound Measuring medium Air, coolant, non-explosive gases Operating frequency 40 kHz ± 2 kHz Outputs 3.5 mm jack s...
View full detailsHCHO Formaldehyde & TVOC Volatile Gas Detector - Hygrometer - Thermometer
HCHO Measuring range 0.00 … 5.00 mg/m³ Reading 0.01 mg/m³ Accuracy ±5 % of the measuring range TVOC Measuring range 0.00 …...
View full detailsAir Sampler
Specifications Parameter Value Particle Measuring range 0 particles/28.3 l ... 1000000 particles/28.3 litr...
View full detailsAir Sampler
Specifications Parameter Value Particles Measuring range 0 pcs/l ... 10000000 pcs/l Measurement ...
View full detailsGas detectors - dust meters are portable or fixed instruments used to detect hazardous gases early and to measure airborne dust/particle concentration. They support leak checks, indoor air quality assessments and worker protection in industrial environments.
Options include single- and multi-gas units for O2, CO, H2S and combustible gases, with audible/visual alarms, data logging and calibration support. You will also find dust meters for PM monitoring with selectable sampling modes and filters, from PCE Instruments & Insize.
Suitable for HSE teams, maintenance, chemical plants and construction sites; choose based on target gas/PM type, measuring range and compliance requirements.
Related Collections
Dust Meters
Dust meters (or particle counters) are air quality monitoring instruments that detect the concentration of suspended particles (Particulate Matter - PM). Their operation is usually based on laser scattering (laser scattering) technology, where a beam of light strikes the particles and the sensor calculates their size and quantity.
- Particle Categories:PM2.5: Fine particles (up to 2.5 μm) that penetrate deep into the lungs and the bloodstream.PM10: Particles (up to 10 μm) such as dust, pollen, and mold.
- Applications:Industry: Dust control in carpentry workshops, cement plants, and mines to protect workers.Cleanrooms (Cleanrooms): Certification of pharmaceutical or electronics production areas.Environment: Monitoring of air pollution and "smog" in cities.
- Features: They include a data recording function (data logging), audible limit-exceedance alerts, and often also measure temperature and humidity in parallel.