Non-contact Ammeter Clamp - Multimeter
PCE-DC 50
| DC A current measurement | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 500 μA | 0.01 μA | ± (1% + 6 digits) |
| 5000 μA | 0.1 μA | ± (1% + 6 digits) |
| 50 A | 0.01 A | ± (2.5% + 5 digits) |
| 1000 A | 0.1 A | ± (2.5% + 30 digits) |
| AC A current measurement | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 500 μA | 0.01 μA | ± (1.5% + 30 digits) |
| 5000 μA | 0.1 μA | ± (1.5% + 30 digits) |
| 50 A | 0.01 A | ± (2.5% + 30 digits) |
| 1000 A | 0.1 A | ± (2.8% + 30 digits) |
| Note: For AC A measurements, the accuracy specification refers to the range from 5% to 100% of the measurement range | ||
| Resistance | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 500 Ω | 0,01 | ± (1% + 9 digits) |
| 5 kΩ | 0,0001 | ± (1% + 5 digits) |
| 50 kΩ | 0,001 | ± (1% + 5 digits) |
| 500 kΩ | 0,01 | ± (1% + 5 digits) |
| 5 MΩ | 0,0001 | ± (3% + 10 digits) |
| 50 MΩ | 0,001 | ± (3.5% + 10 digits) |
| DC V voltage measurement | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 500 mV | 0.01 mV | ± (0.1% + 8 digits) |
| 5V | 0.0001 V | ± (0.1% + 4 digits) |
| 50V | 0.001 V | ± (0.1% + 4 digits) |
| 500V | 0.01 V | ± (0.1% + 4 digits) |
| 600V | 0.1V | ± (0.5% + 4 digits) |
| AC V voltage measurement (50 Hz ... 1000 Hz) | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 500 mV | 0.01 mV |
± (0.8% + 9 digits) (at 50 Hz / 60 Hz) |
| 5V | 0.0001 V | ± (1% + 30 digits) |
| 50V | 0.001 V | ± (1% + 30 digits) |
| 500V | 0.01 V | ± (1% + 30 digits) |
| 600V | 0.1V | ± (1% + 30 digits) |
| Note: The accuracy specification for AC V measurements refers to the range from 5% to 100% of the measurement range | ||
| Capacitance measurement | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 500 nF | 0,01 | ± (3.5% + 40 digits) |
| 5000 nF | 0.1 | ± (3.5% + 10 digits) |
| 50 μF | 0,001 | ± (3.5% + 10 digits) |
| 500 μF | 0,01 | ± (3.5% + 10 digits) |
| 5 mF | 0,0001 | ± (5% + 10 digits) |
| Frequency measurement | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 50 Hz | 0,001 | ± (0.3% + 2 digits) |
| 500 Hz | 0,01 | ± (0.3% + 2 digits) |
| 5 kHz | 0,0001 | ± (0.3% + 2 digits) |
| 50 kHz | 0,001 | ± (0.3% + 2 digits) |
| 500 kHz | 0,01 | ± (0.3% + 2 digits) |
| 5 MHz | 0,0001 | ± (0.3% + 2 digits) |
| 10 MHz | 0,001 | ± (0.3% + 2 digits) |
| Duty cycle | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| 5% ... 95% | 0.1 |
± (1% + 2 digits) (of the measured value) |
|
Pulse width: 100 μs ... 100 ms |
||
| Frequency: 10 Hz ... 10 kHz | ||
| Temperature | ||
| Measuring range | Reading | Accuracy ( from rdg. ) |
| -100°C ... 1000°C / -148 ... 1832 °F | 0.1 | ± (1% + 2.5°C / 4.5°F) |
| General technical data | ||
| Conductor diameter | Maximum 48 mm | |
| Display | Two 50,000-digit lines | |
| Continuity test | 50 ohms / < 50 mA | |
| Diode test | 0.3 mA / 2.8 V DC | |
| Battery indication | Battery icon when battery is low | |
| Overrange indication | OL | |
| Sampling rate | 2 Hz | |
| Exit | Bluetooth | |
| Peak detection (PEAK) | > 1 ms | |
| Thermocouple | Type K | |
| Safety switch | 500 mA fast-acting ceramic | |
| AC Bandwidth (AC A / AC V) | 50 Hz ... 400 Hz | |
| AC Measurement | True RMS | |
| Operating conditions | 5°C ... 40°C / 41 ... 104°F, maximum 80% RH at 31°C | |
| Storage conditions | -20°C ... 60°C / -4 ... 140°F, maximum 80% RH | |
| Power | 9V battery | |
| Automatic power off | After approximately 30 minutes of inactivity | |
| Dimensions (L x H x W) | 230 x 76 x 40 mm / 9 x 3 x 1.6 in | |
| Weight | 315 g / < 1 lb | |
| Safety |
IEC 1010-1 (2001): EN 61010-1 (2001) CAT III 600V CAT II 1000V Rating pollution 2 |
|
Digital Multimeter PCE-DC 50
with clamp with true rms measurement / AC current measurement / Voltage measurement / Temperature measurement / Bluetooth connection / Rubber housing / Hold display / Auto power off / Maximum cable diameter 48 mm / Multiple measurement functions
with clamp with true rms measurement / AC current measurement / Voltage measurement / Temperature measurement / Bluetooth connection / Rubber housing / Hold display / Auto power off / Maximum cable diameter 48 mm / Multiple measurement functions
The PCE-DC 50 meter is a digital device for measuring currents up to 1000 A AC / DC, voltage, frequency, duty cycle, resistance, continuity test, capacitors, and diodes. The diameter of the clamp opening is 48 mm, allowing measurements on large cross-section cables. Thanks to the NCVD function, the operator can check contactlessly whether voltage is applied to a cable.
The PCE-DC 50 has a built-in Bluetooth interface, through which it can be connected to a computer or smartphone and tablet for storing, further processing, and analyzing measurement data. If the computer does not have a Bluetooth interface to connect the device, a Bluetooth adapter is included in the package.
Another special feature of the meter is temperature measurement. Two type K thermocouples can be connected to the meter and take measurements simultaneously. Here, temperatures up to 1000°C / 1832°F can be measured. The housing of the PCE-DC 50 consists of a sturdy plastic, which is additionally coated with rubber and makes the device suitable for use in demanding environments and resistant to drops.
- Sampling rate 2 Hz
- Cover on test sockets
- AC A and AC V measurement
- Bluetooth connection
- Maximum cable diameter 48 mm
- Temperature measurement via 2 type K thermocouples
- Automatic shutdown
- Non-contact voltage detection
Package contents
1 x PCE-DC 50 digital multimeter
1 x Test cable set
1 x Carrying case
1 x Computer software
1 x Bluetooth adapter
2 x Type K thermocouples
1 x 9V battery
1 x Test cable set
1 x Carrying case
1 x Computer software
1 x Bluetooth adapter
2 x Type K thermocouples
1 x 9V battery