Cable Detector
PCE-LT 12
| Measurement operation | |||
| AC voltage | |||
| Measuring range | Reading | Accuracy | |
| 200 mV | 0.1 mV | ± (0.8% + 5 digits) | |
| 2V | 1 mV | ± (0.8% + 5 digits) | |
| 20V | 0.01 V | ± (0.8% + 5 digits) | |
| 200V | 0.1 V | ± (0.8% + 5 digits) | |
| 750V |
1V |
± (0.8% + 5 digits) | |
| Maximum input voltage: 750V AC | |||
| Frequency range: 40 ... 400 Hz | |||
| RMS conversion | |||
| DC voltage | |||
| Measuring range | Reading | Accuracy | |
| 200 mV | 0.1 mV | ± (0.5% + 5 digits) | |
| 2V | 1 mV | ± (0.5% + 5 digits) | |
| 20V | 0.01 V | ± (0.5% + 5 digits) | |
| 200V | 0.1 V | ± (0.5% + 5 digits) | |
| 1000V | 1V | ± (0.8% + 5 digits) | |
| Maximum input voltage: 1000V DC | |||
| AC current | |||
| Measuring range | Reading | Accuracy | |
| 200 μA |
0.1 μA |
± (1.5% + 5 digits) | |
| 2000 μA | 1 μA | ± (1.5% + 5 digits) | |
| 20 mA | 0.01 mA | ± (1.5% + 5 digits) | |
| 200 mA | 0.1 mA | ± (1.5% + 5 digits) | |
| 2 A | 0.001 A | ± (3.0% + 5 digits) | |
| 20 A | 0.01 A | ± (3.0% + 5 digits) | |
| Overload protection at μA, mA: 200 mA / 1000V fuse | |||
| Overload protection at A: 10 A / 500V fuse | |||
| Maximum input current μA: 2000 μA | |||
| Maximum input current mA: 200 mA | |||
| Maximum input current A: 10 A. | |||
| Frequency range: 40 ... 400 Hz | |||
| RMS conversion | |||
| DC current | |||
| Measuring range | Reading | Accuracy | |
| 200 μA | 0.1 μA | ± (1.2% + 5 digits) | |
| 2000 μA | 1 μA | ± (1.2% + 5 digits) | |
| 20 mA | 0.01 mA | ± (1.2% + 5 digits) | |
| 200 mA | 0.1 mA | ± (1.2% + 5 digits) | |
| 2 A | 0.001 A | ± (2.0% + 5 digits) | |
| 20 A | 0.01 A | ± (2.0% + 5 digits) | |
| Overload protection at μA, mA: 200 mA / 1000V fuse | |||
| Overload protection at A: 10 A / 500V fuse | |||
| maximum input current μA: 2000 μA | |||
| maximum input current mA: 200 mA | |||
| maximum input current A: 10 A. | |||
| Resistance | |||
| Measuring range | Reading | Accuracy | |
| 200 Ω | 0.1 Ω | ± (1.0% + 5 digits) | |
| 2 kΩ | 0.001 kΩ | ± (1.0% + 5 digits) | |
| 20 kΩ | 0.01 kΩ | ± (1.0% + 5 digits) | |
| 200 kΩ | 0.1 kΩ | ± (1.0% + 5 digits) | |
| 2 MΩ | 0.001 MΩ | ± (1.0% + 5 digits) | |
| 20 MΩ | 0.01 MΩ | ± (1.0% + 5 digits) | |
| Diode measurement | |||
| Measuring range | Reading | Accuracy | |
| Indicates forward voltage | 1 mV | - | |
| Continuity test | |||
| Measuring range | Reading | Accuracy | |
| Acoustic signal at <70 Ω | 0.1 Ω | - | |
| Other specifications | |||
| Range selection | Automatic and manual | ||
| Measurement with receiver | Detection of cable bridges, cable route detection | ||
| Measurement with network function | Detection of open and closed circuits, | ||
| wrong connection, "pair split", "reverse" connection, | |||
| Network continuity test, control test | |||
| Further measurement function | NCV detection, telephone line test | ||
| Display | LCD, 1999 digits | ||
| Overload indication | "OIL" | ||
| Automatic power off | After 15 minutes of inactivity | ||
| Fuses | F10A / 500V, F200mA / 1000A | ||
| Battery indication | Display when the battery is discharged | ||
| Power | 9V battery | ||
| Operating conditions | 0 ... 40°C / 32 ... 104 °F | ||
| -10 ... 50°C / 14 ... 122 °F | |||
| Dimensions | 195 x 92 x 55 mm / 7.7 x 3.6 x 2.2 in | ||
| Weight | Approximately 400 g / < 1 pound (with batteries) | ||
Digital Multimeter PCE-LT 12
with many measurement functions / Network connection cable analysis / Telephone line testing / Voltage and current measurement / NCV / Backlit display
with many measurement functions / Network connection cable analysis / Telephone line testing / Voltage and current measurement / NCV / Backlit display
The PCE-LT 12 is a versatile measuring instrument. In addition to standard voltage and current measurements, the multimeter can be used for network analysis, that is, to check LAN connections and telephone lines for correct wiring and operation.
Thanks to the cable tracing function, the operator can find the required cable in minimal time in cases of complex wiring.
To check if voltage is applied to a cable, the detector features an NCV (Non-Contact Voltage) function. Then, if it detects voltage without contact, it activates an audible and visual signal. Thanks to this non-contact measurement function, accidents due to electric shock are reduced.
- Extensive network connection testing
- Telephone line testing
- Function for finding audio cables
- Robust housing for portable use
- Measurement of voltage, current, resistance
- Non-contact voltage detection
Package contents
1 x Digital Multimeter PCE-LT 12
1 x Receiver
1 x Pair of Test Leads
1 x Connection Adapter Holder
2 x 9V Batteries
1 x User manual
1 x Receiver
1 x Pair of Test Leads
1 x Connection Adapter Holder
2 x 9V Batteries
1 x User manual