Skip to content
2102231624 - Δωρεάν μεταφορικά άνω 50€ - Τιμές χωρίς ΦΠΑ
2102231624 - Δωρεάν μεταφορικά άνω 50€ - Τιμές χωρίς ΦΠΑ

Anemometer - Thermometer - Hygrometer - Barometer (Dew point, Wet Bulb, Wind chill)

PCE-EM 890

Κωδικός Range Reading Accuracy Τιμή Στοκ
PCE-EM 890 0.4-20 m/s 0.1 m/s 3% €392,00 5-8 εργάσιμες
Τιμές χωρίς ΦΠΑ 24%
Measurement operation Measuring range Reading Accuracy
Wind Speed 80 ... 3937 ft/min 1 ft/min ± 3% of the measured value
  0.4 ... 20 m/s 0.1 m/s  
  1.4 ... 72 km/h 0.1 km/h  
  0.9 ... 44.7 mph 0.1 mph  
  0.8 ... 38.8 Knots 0.1 Knots  
       
Air temperature Measuring range Reading Accuracy
  0 ... 50°C / 32 ... 122°F     0.1°C / 0.18°F ± 1.2°C / 2.16°F
       
Humidity Measuring range Reading Accuracy
  10 ... 95% rH 0.1% rH <70% rH: ± 4% rH
      >70% rH: ± 4 of the measured value +1.2% rH
       
Barometric air pressure Measuring range Reading Accuracy

10 ... 999.9 hPa 0.1 hPa ± 1.5 hPa
  1000 ... 1100 hPa 1 hPa ± 2 hPa
       
UV A 290 ... 390 nm Measuring range Reading Accuracy

0 .... 1999 µW/m² 0.1 µW/m² ±(4% of measured value + 2 digits)
  2 ... 20 mW/m² 0.01 mW/m²  
       
Outside temperature Measuring range Reading Accuracy
(Pt1000 input) -10 ... 70 °C / 14 ... 158 °F                                      0.1°C / 0.18 ± 1.2°C / 2.16°F
       
       
Air supply Measuring range Reading  
  0.024 ... 3600 cm    0.001 cm  
    0.01 cm  
    0.1 cm  
    1 cm  
       
  Measuring range Reading  
Dew point -25.3 ... 49°C / 13.54 ... 120.2°F 0.1°C / 0.18°F  
       
Wet bulb temperature Measuring range Reading  
  -5.4 ... 49°C / 22.28 ... 120.2°F 0.1°C / 0.18°F  
       
Discomfort index Measuring range Reading Accuracy
  0 ... 100°C / 32 ... 212°F 0.1°C / 0.18°F ± 2°C / 3.6°F
       
Cold sensation (wind chill) Measuring range Reading Accuracy
  -9.4 ... 44.2°C / 15.8 ... 111.56°F 0.1°C / 0.18°F ± 2°C / 3.6°F
       
Height above sea level Measuring range Reading Accuracy
  -2000 ... 9000 m / -6561 ... 29527 feet 1 m / 3 ft 3" ± 15 m
       
General technical data for the anemometer
Display LC
  Character height 8 mm
Measurement functions  Wind speed / temperature
Measurement parameters Humidity / temperature
  UV
  Air pressure
  Volume flow
  Dew point
  Wet bulb temperature
  Dew
  Thermal stress index
  Height above sea level
  External temperature above 1000 Pt
   
Power CR2032 3V batteries
Consumption about 5 mA
Operating conditions 0 ... 50°C / 32 ... 122°F / max 80% rH
Dimensions 120 x 45 x 20 mm / 4.7 x 1.7 x 0.7"
Weight about 160 g / < 1 lb
   


PCE-EM 890 Anemometer
Measuring device for recording various environmental data / Various measuring functions / MAX / MIN measurement / High accuracy 

The PCE-EM 890 anemometer is an instrument for measuring environmental conditions. The anemometer gives you an accurate measurement very quickly. Due to its small size and light weight, this anemometer is a handy information system for weather conditions. It is possible to switch between measurement functions with the press of a button. Thus, this anemometer is ideal for technicians, sailors, farmers, and many other people whose activities are significantly affected by weather conditions. 

With the meter, you can read wind speed, temperature, wind chill, dew point, relative humidity, heat index, barometric pressure, and altitude above sea level. The anemometer offers you the functions of single measured value, minimum value, maximum value measurement.

Explanation of various environmental conditions:

Wind Chill
The wind chill is the temperature perceived by the human body under the influence of low temperatures and wind. 

Air pressure
The air pressure at any location in the Earth's atmosphere is the hydrostatic air pressure prevailing at that location. This pressure corresponds to the weight of the air column above the Earth's surface or a body on it. The average atmospheric pressure at sea level is 101325 Pa = 1013.25 hPa = 101.325 kPa and therefore is part of the normal conditions.

Dew Point / Dew Point Temperature
Air can absorb more water vapor as the temperature increases. When the temperature of a building material or air decreases, and when the relative humidity reaches At 100%, the excess water vapor condenses. The boundary area is called the dew point. Buildings must be designed so that the dew point temperature inside the airtight layer is not lower. This prevents condensation formation and the resulting structural damage or mold. Air currents through the airtight layer are particularly harmful. In this case, a drop below the dew point is always expected. The wet bulb temperature, which plays an important role in the air conditioning industry, for example, is a very important parameter in many other fields.

- compact and robust construction
- high accuracy
- very precise impeller, smooth operation
- easy-to-read digital display
- backlight
- interchangeable impeller
- Max-Min measurement
- 11 measuring functions in one device


Package contents
1 x PCE-EM 890 Anemometer
1 x CR2032 batteries