PCE-EM 890 - Anemometer- Thermometer- Hygrometer- Barometer
Κωδικός | Εύρος | Ανάγνωση | Ακρίβεια | Τιμή | Στοκ | ||
---|---|---|---|---|---|---|---|
PCE-EM 890 | 0.4-20 m/s | 0.1 m/s | 3% | €392,00 | 2-5 εργάσιμες |
Τιμές χωρίς ΦΠΑ 24%
Measurement function | Measurement range | Analysis | Accuracy |
Wind speed | 80 ... 3937 ft/min | 1 ft/min | ± 3% of measured value |
0.4 ... 20 m/s | 0.1 m/s | ||
1.4 ... 72 km/h | 0.1 km/h | ||
0.9 ... 44.7 mph | 0.1 mph | ||
0.8 ... 38.8 Knots | 0.1 Nodes | ||
Air temperature | Measurement range | Analysis | Accuracy |
0 ... 50°C / 32 ... 122°F | 0.1°C / 0.18°F | ± 1.2°C / 2.16°F | |
Moisture | Measurement range | Analysis | Accuracy |
10 ... 95% rH | 0.1% rH | <70% rH: ± 4% rH | |
>70% rH: ± 4 of the measured value +1.2% rH | |||
Barometric- | Measurement range | Analysis | Accuracy |
air pressure | 10 ... 999.9 hPa | 0.1 hPa | ± 1.5 hPa |
1000 ... 1100 hPa | 1 hPa | ± 2 hPa | |
UV A 290 ... 390 nm | Measurement range | Analysis | Accuracy |
0 .... 1999 µW/m² | 0.1 µW/m² | ±(4% of measured value + 2 digits) | |
2 ... 20 mW/m² | 0.01 mW/m² | ||
Outside temperature | Measurement range | Analysis | Accuracy |
(Input Pt1000) | -10 ... 70 °C / 14 ...158 °F | 0.1°C / 0.18 | ± 1.2°C / 2.16°F |
Air supply | Measurement range | Analysis | |
0.024 ... 3600 cm | 0.001 cm | ||
0.01 cm | |||
0.1 cm | |||
1 cm | |||
Measurement range | Analysis | ||
Dew point | -25.3 ... 49°C / 13.54 ... 120.2°F | 0.1°C / 0.18°F | |
Liquid bulb temp | Measurement range | Analysis | |
-5.4 ... 49°C / 22.28 ... 120.2°F | 0.1°C / 0.18°F | ||
Stress discomfort index | Measurement range | Analysis | Accuracy |
0 ... 100°C / 32 ... 212°F | 0.1°C / 0.18°F | ± 2°C / 3.6°F | |
Feeling cold | Measurement range | Analysis | Accuracy |
-9.4 ... 44.2°C / 15.8 ... 111.56°F | 0.1°C / 0.18°F | ± 2°C / 3.6°F | |
Height above sea level | Measurement range | Analysis | Accuracy |
-2000 ... 9000 m / -6561 ... 29527 ft | 1 m / 3 ft 3" | ± 15 m | |
General technical data for the anemometer | |||
Display | LC screen | ||
Character height 8 mm | |||
Measurement functions | Wind speed / temperature | ||
Measurement parameters | Humidity / temperature | ||
UV | |||
Air pressure | |||
Volume flow | |||
Dew point | |||
Liquid bulb temp | |||
Cool | |||
Heat stress index | |||
Height above sea level | |||
Outside temperature above 1000 Pt | |||
Provision | CR2032 3V batteries | ||
Current consumption | about 5-mA | ||
Operating conditions | 0 ... 50°C / 32 ... 122°F / max. 80% rH | ||
Dimensions | 120 x 45 x 20mm / 4.7 x 1.7 x 0.7" | ||
Weight | approx. 160g / < 1lb | ||
PCE-EM 890 anemometer
Weather measuring device for recording various environmental data / Various measurement functions / MAX / MIN measurement / High accuracy
The PCE-EM 890 anemometer is an instrument for measuring environmental conditions. The anemometer gives you an accurate measurement very quickly. Due to its small dimensions and light weight, this anemometer is an easy-to-use weather information system. It is possible to switch between measurement modes at the touch of a button. Thus, this anemometer is ideal for technicians, sailors, farmers and many other people whose activities are significantly affected by weather conditions.
With the gauge, you can read wind speed, temperature, chill, dew point, relative humidity, heat index, barometric pressure and altitude. The anemometer offers you the functions of single measured value, minimum value, maximum value measurement.
Explanation of various environmental conditions:
Feeling cold
The feeling of cold is the temperature that the human body feels under the influence of low temperatures and the presence of wind.
Air pressure
The air pressure at any location in the Earth's atmosphere is the hydrostatic air pressure prevailing at that location. This pressure is consistent with the weight of the air column on the surface of the earth or a body on it. The mean atmospheric pressure of the atmosphere at sea level is 101325 Pa = 1013.25 hPa = 101.325 kPa and is therefore part of normal conditions.
Dew Point / Dew Point Temperature
Air can absorb more water vapor with increasing temperature. When the temperature of a building material or air decreases, and when the relative humidity reaches 100%, the excess water vapor condenses. The boundary region is called the dew point. Buildings must be designed so that the dew point temperature inside the airtightness layer is not lower. This avoids the formation of condensation and the resulting structural damage or mold. Air currents through the airtightness layer are particularly harmful. In this case, a drop below the dew point is always expected. The wet bulb temperature, which plays an important role in the air conditioning industry, for example, is a very important parameter in many other areas.
- compact and robust construction
- high accuracy
- very precise impeller, smooth operation
- easy to read digital display
- backlight
- replaceable impeller
- Max-Min measurement
- 11 measurement functions in one device
Package contents
1 x PCE-EM 890 Anemometer
1 x CR2032 batteries
1 x User Manual
1 x CR2032 batteries
1 x User Manual