PCE-IT100 - Resistance Meter
Measurement range | |
AC Voltage (40 ... 400 Hz) | 750V |
Reading | 1V |
Accuracy | ± 0.8% ± 3 dgt |
DC Voltage | 1000V |
Reading | 1V |
Accuracy | ± 1.2% ± 10 dgt |
Resistance | 40 Ω / 400 Ω |
Reading | 0.01 Ω / 0.1 Ω |
Accuracy | ± 1.2% ± 3 dgt |
Insulation resistance | 4 MΩ / 40 MΩ / 400 MΩ / 4000 MΩ |
Reading | 0.001 MΩ / 0.01 MΩ / 0.1 MΩ / 1 MΩ |
Insulation resistance | |
125V |
± (2% + 10 dgt) / ± (2% + 10 dgt) / ± (4% + 5 dgt) / ± (5% + 5 dgt) |
250V |
± (2% + 10 dgt) / ± (2% + 10 dgt) / ± (3% + 5 dgt) / ± (4% + 5 dgt) |
500V |
± (2% + 10 dgt) / ± (2% + 10 dgt) / ± (4% + 5 dgt) / ± (4% + 5 dgt) |
1000V |
± (3% + 10 dgt) / ± (2% + 10 dgt) / ± (2% + 5 dgt) / ± (4% + 5 dgt) |
Continuity test | Audible signal: ≤ 35 Ω, test current ≤ 200-mA |
Power supply | 6 x 1.5V AA battery |
Environmental conditions |
0 ... 40°C / 32 ... 104°F, <80% RH (operation) -10 ... 60°C / 14 ... 140°F, <70% RH (bearing) |
Dimensions | 200 x 92 x 50 mm / 7.9 x 3.6 x 2 in |
Weight | 700g / 1.5lb (with battery) |
Standards | IEC10101, CAT III 1000V |
Insulation meter PCE-IT100
For insulation resistance up to 4000 MΩ / CAT III 1000V / Easy handling / Simple or continuous measurement / Maximum and minimum value function
For insulation resistance up to 4000 MΩ / CAT III 1000V / Easy handling / Simple or continuous measurement / Maximum and minimum value function
The PCE-IT100 insulation tester detects with auxiliary voltages of 125V, 250V, 500V and 1000V insulation resistances up to 4000 MΩ. In addition, it is used to measure resistances up to 400 Ω and AC and DC voltage. A continuity tester with audible signal is also part of the isolation meter equipment. The meter has a data hold function as well as a maximum and minimum value recording function.
The large digits, backlit display and ease of use make the PCE-IT 100 ideal for demanding environments with limited lighting. The insulation meter comes with a set of test leads with test probes, a test lead with alligator clips and 6 batteries.
Observed limits for insulation measurement
- For new installations (dry rooms): 1000 ohms x volts of operating voltage (eg at 230 volts > 230 kOhms)
- For new installations (wet areas, outdoor areas): 500 ohms x volts operating voltage
- Grounding in devices: 1000 ohms x volt operating voltage
- Protected devices: 2 MOhm
- Power tools: 2 MOhm
- Ultra low voltage: 250 kOhm
- Electrical measuring devices: 5 MOhm
- Common test voltage values are 100 V for low voltage and telecommunication systems, 500 V for building installations and household appliances, 1000 V for low voltage motors and transformers
- Wide measurement range
- 4 different test voltages up to 1 kV
- Automatic power
- Automatic power
- Auto power off function
- Safety: EN 61010-1, CAT III 1000V
- Backlit screen
- Carrying case included
- Simple measurement and continuous measurement
- Safety: EN 61010-1, CAT III 1000V
- Backlit screen
- Carrying case included
- Simple measurement and continuous measurement
Package contents
1 x PCE-IT100 insulation meter 1 x Set of test leads
1 x Crocodile clip on cable 1 m / 3.3 ft
6 x 1.5V AA battery
1 x Carrying strap
1 x User Manual
1 x Carrying case