CODEPCE-SLT
CODEPCE-SLT
Permanent installation sound level meter with alarm, 4-20 mA output and 220V display
- 30 ... 130 dB, 3 ranges
- Resolution 0.1 dB
- Accuracy ±1.5 dB
- 4 ... 20 mA output
- Class II per IEC 61 672
- Relay alarm output
Same-day dispatchfor orders placed by 15:00
Free shippingon orders over €80 (incl. VAT)
ISO 17025 calibrationupon request
Availability & price
| Code | Availability | excl. VAT | incl. VAT | Certificate | Cart |
|---|---|---|---|---|---|
| PCE-SLT |
€664,00
|
€823,36
|
- 30 ... 130 dB, 3 ranges
- Resolution 0.1 dB
- Accuracy ±1.5 dB
- 4 ... 20 mA output
- Class II per IEC 61 672
- Relay alarm output
The PCE-SLT is a class II (type 2) sound level meter for permanent installation. It measures sound pressure level from 30 to 130 dB in three ranges, with 0.1 dB resolution and ±1.5 dB accuracy, and triggers an audible or visual alarm.
The system consists of a wall-mountable acoustic sensor on a 1.5 m / 4.92' cable, a transmitter with 4 ... 20 mA output and an IP 65 digital indicator. It is used for long-term, continuous monitoring of occupational noise exposure limits in foundries, factories and manufacturing production floors.
Highlights
- Measuring range 30 ... 130 dB in 3 ranges
- Resolution 0.1 dB, accuracy ±1.5 dB
- A frequency weighting, 1/2" precision electret microphone
- Transmitter with 4 ... 20 mA output
- Relay alarm output 5 A / 240 V AC
- Wall-mounted sensor on 1.5 m / 4.92' cable
- IP 54 transmitter, IP 65 digital indicator
- Mains powered 90 ... 260 AC V
| Sensor | |
|---|---|
| Measuring range | 30 ... 130 dB in 3 ranges: I. 30 ... 80 dB(A) II. 50 ... 100 dB(A) III. 80 ... 130 dB(A) |
| Resolution | 0.1 dB |
| Accuracy | ±1.5 dB |
| Frequency weighting | A |
| Power supply | Via transmitter |
| Cable length (sensor to transmitter) | 1.5 m / 4.92' |
| Operating conditions | 0 ... +50 °C / +32 ... +122 °F, max. 85 % RH |
| Microphone | 1/2" precision electret |
| Standard | IEC 61 672 (Class II) |
| Transmitter | |
| Housing | ABS plastic |
| Power supply | 90 ... 260 AC V |
| Calibration | Adjustable by set screw |
| Output | 4 ... 20 mA |
| Protection class | IP 54 ingress protection rating |
| Operating conditions | 0 ... +50 °C / +32 ... +122 °F, max. 85 % RH |
| Digital indicator | |
| Transmitter input signal | 4 – 20 mA |
| Indicator | - 1999 ... 9999 (1 ... 3 decimals, according to the measurement value / chosen by the user) |
| Programming data (decimals, limit value ..) | Saved in the unit |
| Regulation output | 3 points (Com, NO, NC) |
| Alarm output | Relay output: 5 A / 240 V AC |
| Power | 90 ... 260 ACV / 50 ... 60 Hz |
| Dimensions / Switchboard according to DIN | 92 (+ 0.8) mm x 45 (+ 0.5) mm |
| Weight | Approx. 250 g / 0.56 lb |
| Operating conditions | 0 ... +50 °C / +32 ... +122 °F, max. 85 % RH |
| Protection class | IP 65 ingress protection rating |
- 1×PCE-SLT noise meter (consisting of 1 x acoustic sensor on a 1.5 m / 4.92' long cable and a transmitter)
- 1×Wall-mounting bracket for sensor
- 1×Digital indicator
- 1×User manual