DC Electrostatic Field Meter, kV
PCE-SFS 10
| Electromagnetic field | |
| Measuring range | ±60 kV DC |
| Reading | ±20 kV DC: |
| -60 ... -20 kV DC: 0.01 kV DC | |
| +20 ... +60 kV DC: 0.1 kV DC | |
| Accuracy |
±5 % of the measured value |
| Temperature | |
| Measuring range | -40 ... 123.8 °C / -40 ... 254.8 °F |
| Reading | 0.1 °C |
| Accuracy | ±1.5 °C |
| Humidity | |
| Measuring range | 0 ... 100 % RH |
| Reading | 0.1 % RH |
| Accuracy | ±4.5 % RH |
| Further specifications | |
| Response time | <100 ms |
| Acoustic alarm | when the measuring device is activated, |
| 5 seconds before automatic shutdown, | |
| when the measuring range is exceeded | |
| Automatic power off | after 5 minutes |
| Power | 9 V battery |
| Operating time | > 20 hours |
| Operating conditions | 0 ... 40 °C / 32 ... 104 °F, 0 ... 60% RH, non-condensing |
| Dimensions | 123 x 70.4 x 21.5 mm / 4.8 x 2.7 x 0.84" |
| Weight | 147 g / 5.1 oz |
Electromagnetic radiation meter with measurement range ±60 kV DC / Battery status indicator /
Simple operation / Grounding cable with crocodile clip / Alignment via two lasers /
For portable use / Measurement of ambient temperature and humidity
Simple operation / Grounding cable with crocodile clip / Alignment via two lasers /
For portable use / Measurement of ambient temperature and humidity
Such electrostatic charges can be detected with the Gauss meter. Therefore, the electromagnetic field meter is used for testing in ESD-protected laboratories. The measurement range is ±60 kV DC.
The meter can be grounded with a crocodile clip included in the package to prevent measurement loss due to electric shock. The lasers on the meter are used for optimal alignment of the sensors.
Besides measuring radiation, the PCE-SFS 10 measures ambient temperature and humidity. The meter is powered by a 9 V battery with a maximum autonomy of 20 hours. The current battery status is displayed on the screen.
The meter can be grounded with a crocodile clip included in the package to prevent measurement loss due to electric shock. The lasers on the meter are used for optimal alignment of the sensors.
Besides measuring radiation, the PCE-SFS 10 measures ambient temperature and humidity. The meter is powered by a 9 V battery with a maximum autonomy of 20 hours. The current battery status is displayed on the screen.
- Battery life up to 20 hours
- Measurement range ±60 kV DC
- Acoustic signal when exceeding the measured value
- Temperature and humidity display
- Laser for alignment of the measuring device
- Readable display
Package contents
1 x PCE-SFS 10 meter
1 x Grounding cable
1 x Carrying bag
1 x 9 V battery
1 x User manual
1 x Grounding cable
1 x Carrying bag
1 x 9 V battery
1 x User manual