Ultrasonic Thickness Gauge Accessories
34 από 34 products
Gel for Ultrasonic Thickness Gauges 100 ml
100 ml bottleFor ultrasonic contact transducersArticle number TT-GELUltrasonic contact gel (couplant) for use with ultrasonic contact transducers. ...
View full details
Gel for Ultrasonic Thickness Gauges 25 ml
Gel for General Purpose Ultrasonic Calipers 250 ml
High Temperature Gel for Ultrasonic Thickness Gauges 100 ml
Usable up to 350°C / 662°F100 ml contentFor ultrasonic thickness measurementReliable probe-to-surface contactThe K-Gel is a high-temperature coupli...
View full details
Standard Test Blocks for Ultrasonic Thickness Gauges
Specifications Material: 45# steel (equivalent to C45) Supplied with manufacturer inspection certificate Material of step wedge blocks can be cust...
View full details
Ultrasonic Probe 1.5 - 200 mm - General Purpose (for the ISU-300D)
Specifications Compatibility: ISU-300D Probe code: ISU-T07 Measuring modes: T-E (Transmit-Echo), E-E (Echo-Echo) Frequency: 5.0MHz Trans...
View full details
Ultrasonic Probe 0.8 - 300 mm - General Purpose (for the ISU-250C)
Specifications Compatibility: ISU-250C ultrasonic thickness gauge Probe type: Ultrasonic, general-purpose Measuring range: 0.8~300 mm Appl...
View full details
Ultrasonic Probe 0.7 - 20 mm - for Small Pipes Ø10 x 1.0 mm -
Ultrasonic Probe 0.7 - 50 mm - for Thin Materials
Specifications Type: Ultrasonic thickness gauge probe/transducer Measuring range (on steel): 0.7 ~ 50 mm Frequency: 7.5 MHz Probe diameter...
View full details
Ultrasonic Probe 2.0 - 400 mm - for Cast Iron
Specifications Type: Ultrasonic transducer/probe for ultrasonic thickness gauges Probe code: ISU-T12 Application: for casting iron Measuri...
View full details
Ultrasonic Probe 2.0 - 200 mm - High Temperatures <350° C
Specifications Type: Ultrasonic transducer/probe for an ultrasonic thickness gauge Probe diameter (Ød): 15 mm Frequency: 5.0 MHz Measuring...
View full details
USB Programming Unit for PCE Digital Indicators
Sets up PCE digital indicatorsUSB connection to PCFree LPCon softwareSets alarm threshold valuesReads out indicated valuesThe PCE-PD14 programming ...
View full details
Ultrasonic Probe 3-200 mm - for Fiberglass and organic material
Specifications Code: ISU-T25 (optional) Mode: T-E Frequency: 1.0MHz Probe diameter (Ød): 26mm Measuring range: 3~200mm Applicable temp...
View full details
Dual Ultrasonic Probe for Castings
Specifications Probe type: Dual element Frequency: 2 MHz Diameter (Ød): 17 mm Measuring range: 3~700 mm Minimum pipe size (diameter × wa...
View full details
Dual Ultrasonic Probe for Cylindrical Surfaces
Specifications Probe type: Dual element Frequency: 2MHz / 3MHz / 5MHz / 7.5MHz (model-dependent) Measuring range: 0.8~700mm (model-dependent...
View full details
Dual General Purpose Ultrasonic Probe
Specifications Type: Dual element ultrasonic probe Frequency: 2~7.5 MHz (model-dependent) Probe diameter (Ød): 9~17 mm (model-dependent) M...
View full details
Dual Ultrasonic Probe for Cylindrical Surfaces and Small Workpieces
Specifications Probe type: Dual element Frequency: 7.5MHz Diameter (Ød): 9mm Measuring range: 0.8~50mm Min. size of pipes (diameter x wa...
View full details
Dual Ultrasonic Probe for High Temperatures 310°C
Specifications Probe type: Dual element Frequency: 3MHz Diameter (Ød): 15mm Measuring range: 2~200mm Min. size of pipes (diameter x wall...
View full details
Ultrasonic Probe for Large Thicknesses
Specifications Type: Ultrasonic thickness probe (transducer) Application: ultra-thick workpieces Measuring range (I-E): 30~2000mm Measurin...
View full details
General Purpose Ultrasonic Probe
Specifications Type: Ultrasonic probe (single element and dual element versions available) Operating frequency: 2–15 MHz (model-dependent) P...
View full details
TAPERED DELAY BLOCK (for ISU-S15-P06)
Specifications Type: Tapered Delay Block Compatibility: for ISU-S15-P06 Description The Tapered Delay Block is an accessory (delay block) use...
View full details
Ultrasonic Probe (ISU-810D) for High Temperatures
Ultrasonic Probe (ISU-810D) for Small Diameters
Ultrasonic Probe (ISU-810D) for cylindrical surfaces and small parts
Ultrasonic Probe (ISU-810D) General Purpose
Ultrasonic Probe (ISU-810D) General Purpose
Ultrasonic Probe (ISU-810D) Fiber Glass and Organic Material
Ultrasonic Probe (ISU-810D) Cast Iron and Large Thicknesses
Ultrasonic Probe 0.8 - 300 mm - General Use (for ISU-200D)
Ultrasonic Probe 3.0 - 400 mm - for Cast Steel (for ISU-200D)
Ultrasonic Probe 0.75 - 50 mm - for Thin Materials (for ISU-200D)
Ultrasonic Probe 2.0 - 200 mm - High Temperature <310°C (for ISU-200D)
Ultrasonic Probe 0.8 - 225 mm - for Wall Thickness (for ISU-200D)
High-Temperature Couplant Gel for Ultrasonic Thickness Gauges (ISU-HT5)
Ultrasonic thickness gauge accessories are the parts and consumables that keep thickness readings reliable on metals, plastics, fiberglass and composites without damaging the part — in corrosion surveys, pipework, tanks, plate and castings.
This collection includes replacement ultrasonic probes (transducers) from Insize for the ISU-200D, ISU-250C, ISU-300D and ISU-810D gauges; dual-element probes from 2 to 7.5 MHz for corroded and curved surfaces; probes for thin material and small pipes (from 0.7 mm), for cast iron and very thick parts (up to 2000 mm), for fiberglass, and for high temperatures (up to 310°C); plus a tapered delay block. Completing the range are couplant gels from Insize and PCE Instruments — 25 to 250 ml, including high-temperature versions rated up to 350°C — and step blocks for checking and calibrating the gauge.
Choosing a probe
- Compatibility — each probe is made for a specific gauge: ISU-200D-… codes fit the ISU-200D, ISU-810D-… codes fit the ISU-810D, the ISU-T08 fits the ISU-250C and the ISU-T07 fits the ISU-300D. Compatibility is listed on every product page.
- Frequency — 7.5 MHz for thin material and small pipes, 5 MHz for general use, 2 MHz or lower for cast iron, castings, fiberglass and thick sections.
- Dual or single element — dual-element probes are the first choice for corroded, rough and curved surfaces; single-element probes suit smooth surfaces and precision work.
- Temperature — hot surfaces need a high-temperature probe and a high-temperature couplant; standard gel is rated to about 80°C.
- Minimum pipe size — for small-diameter pipe choose a probe with a small face (e.g. Ø10 × 1.0 mm for the ISU-T04).
FAQ
Which probe fits my gauge? Check your gauge model (e.g. ISU-200D, ISU-810D) and pick a probe that lists the same model under Compatibility. If in doubt, send us your gauge's model code.
Why do I need couplant gel? Ultrasound doesn't travel through air; couplant fills the gap between the probe and the surface so the reading is stable. On hot surfaces standard gel evaporates, so use a high-temperature couplant.
When should a probe be replaced? When its contact face is worn, or when the gauge no longer reads correctly on a step block of known thickness. Step blocks let you check this regularly.
See also our ultrasonic thickness gauges and the ultrasonic thickness gauge guide.