Ammeter clamp 2A - 1mA
PCE-DC3
|
Alternating current AC (50 / 60 Hz) |
Range / Reading / Accuracy 2 A / 1-mA / ± 2.8% + 10 dgt 80 A / 100-mA / ± 3.0% + 8 dgt |
| Direct current DC |
Range / Reading / Accuracy 2 A / 1-mA / ± 3.0% + 10 dgt 80 A / 100-mA / ± 3.0% + 8 dgt |
|
AC overload protection (non-contact) |
100V AC to 600V AC 50 / 60 Hz |
| Flashlight illumination | White LED |
| Conductor diameter | 18 mm / 0.7 in max |
| Display | 3 2/3 digit LCD with backlight |
| Power supply | Batteries 2 - 1.5 V AAA |
| Case | PVC |
| Dimensions | 164 x 65 x 32 mm / 6.4 x 2.5 x 1.2 in |
| Weight | 175 g / < 1 Lb |
| Standards |
EN61010-1; CAT II / 600V EN61010-2-032; CAT III / 300V |
DCA zero point function / AC/DC current measurement up to 80 A /
Automatic range selection / Clamp opening: 18 mm / 0.7"
The PCE-DC3 is designed for indirect measurement of AC/DC currents with high reading. It features a non-contact voltage test function and a flashlight to illuminate the measurement point. The compact size of this current clamp allows its use in hard-to-reach places.
The large, illuminated display of these measuring clamps ensures very good readability even in dark environments, such as switch cabinets and cable ducts. The non-contact voltage test function not only supports you in detecting dangerous voltage potentials but also provides you with an accurate tool for determining cable break points in cable reels, extension cords, and device connection cables.
- AC/DC current measurement up to 80 amps
- Hold function
- DCA zero setting
- Built-in flashlight
- Automatic range selection
- Jaw opening 18 mm / 0.7 in
Package contents
1 x Case
2 x Batteries
1 x User manual