PCE-SFS 10 - Electrostatic Field Meter - Thermometer - Hygrometer
Electromagnetic field | |
Measurement range | ±60 kV DC |
Reading | ±20 kV DC: |
-60 ... -20 kV DC: 0.01 kV DC | |
+20 ... +60 kV DC: 0.1 kV DC | |
Accuracy |
±5 % of the measured value |
Temperature | |
Measurement range | -40 ... 123.8 °C / -40 ... 254.8 °F |
Reading | 0.1 °C |
Accuracy | ±1.5 °C |
Humidity | |
Measurement range | 0 ... 100 % RH |
Reading | 0.1% RH |
Accuracy | ±4.5% RH |
Further specifications | |
Response time | <100 ms |
Audible alarm | when switching on the measuring device, |
5 seconds before automatic shutdown, | |
when the measurement range is exceeded | |
Automatic shutdown | 5 minutes later |
Power supply | 9V battery |
Operating time | > 20 hours |
Operating conditions | 0 ... 40 °C / 32 ... 104 °F, 0 ... 60% RH, non-condensing |
Dimensions | 123 x 70.4 x 21.5mm / 4.8 x 2.7 x 0.84" |
Weight | 147g / 5.1oz |
Electromagnetic radiation meter with measuring range ±60 kV DC / Battery status indicator /
Simple operation / Ground cable with alligator clip / Alignment via two lasers /
For portable use / Ambient temperature and humidity measurement
Simple operation / Ground cable with alligator clip / Alignment via two lasers /
For portable use / Ambient temperature and humidity measurement
Such electrostatic charges can be found with the Gauss meter. Therefore, the electromagnetic field meter is used for testing in laboratories with ESD protection. The measurement range is ±60 kV DC.
The meter can be earthed with an alligator clip included in the package to prevent loss of measurement due to electric shock. Lasers in the meter are used to optimally align the sensors.
In addition to measuring radiation, the PCE-SFS 10 measures ambient temperature and humidity. The meter is powered by a 9 V battery with a maximum autonomy of 20 hours. The current battery status is shown on the screen.
The meter can be earthed with an alligator clip included in the package to prevent loss of measurement due to electric shock. Lasers in the meter are used to optimally align the sensors.
In addition to measuring radiation, the PCE-SFS 10 measures ambient temperature and humidity. The meter is powered by a 9 V battery with a maximum autonomy of 20 hours. The current battery status is shown on the screen.
- Battery life up to 20 hours
- Measuring range ±60 kV DC
- Audible signal when the measured value is exceeded
- Temperature and humidity display
- Laser for alignment of the measuring device
- Easy to read display
Package contents
1 x PCE-SFS 10 Meter
1 x Ground wire
1 x Carrying bag
1 x 9V battery
1 x User Manual
1 x Ground wire
1 x Carrying bag
1 x 9V battery
1 x User Manual