Environmental Sound Level Meter Class II - USB - Octave Band Operation

Κωδικός Τιμή Στοκ
PCE-428-EKIT €4.590,00 Κ.Π. Ρωτήστε *

* Κ.Π. : Κατόπιν Παραγγελίας

Τιμές χωρίς ΦΠΑ 24%

Measurement range

25 ... 136 dBA

Accuracy

Class 2

Frequency range

20 Hz ... 12.5 kHz

Standards

GB/T3785.1-2010
GB/T3785.2-2010
IEC60651:1979
IEC60804:2000
IEC61672-1:2013
ANSI S1.4-1983
ANSI S1.43-1997

Frequency analysis

Octave band filter: 20 Hz ... 8 kHz
1/3 octave band filter: 20 Hz ... 12.5 kHz

Microphone

1/2" Class 2 measurement microphone
Sensitivity: 40 mV/PA
Frequency range: 20 Hz ... 12.5 kHz
Connection: TNC
Power supply: ICCP Standard

Data logging interval

1 s ... 24 h (adjustable)

Measurement modes

LXY(SPL), LXeq, LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN. 

X = Frequency weighting: A, B, C, Z; 
Y = Time weighting: F, S, I; 
N = Statistics in %: 1 ... 99 %

24-hour measurement

Automatic measurement with data storage

Frequency weightings

A, B, C, Z

Time weightings

Fast (F), Slow (S), Pulse (I), Peak

Background noise

Microphone: 20 dB(A), 26 dB(C), 31 dB(Z)
Electronics: 14 dB(A), 19 dB(C), 24 dB(Z)

AD converter

24 bit

Sampling rate

Standard: 48 kHz
LN mode: 20 ms

Measurement display

Numeric
Bar chart
Graphic

Display

Backlit LCD 160 x 160 pixel

Memory

Micro SD card 4 GB

Outputs

USB
RS232

Voltage output

AC 5V RMS
DC 10 mV/db

Alarm

Adjustable

Power supply

4 x 1.5 V AA batteries
12 V / 1 A power plug
5 V / 1 A USB

Operating time Battery operation

minimum 10 h

Dimensions

70 x 300 x 36 mm / 2.76 x 11.81 x 1.42" (W x H x D)

Weight

~ 620 g / 1.4 lbs (with batteries)

Carrying case PELI 1510 with foam grid rollers
Sealing class IP65 (Waterproof)
Sound level meter kit
Connections in the case Microphone: TNC
12 V Charging voltage: XLR
110 V / 230 V Charging voltage: PowerCon TRU
   
Charger Victron Blue Smart 12 V / 4 A IP65 (Waterproof)
Internal batteries 2 x 12 V / 12 Ah lead gel
Operating time with battery minimum 10 days
   
Power supply with charger EU version: 180 ... 265 V AC
with charger US version: 100 ... 130 V AC
Battery operation: 2 x 12 V / 12 Ah
   
Cable length Microphone cable: 2 m / 6 ft 6" with TNC connector TNC
Power supply: 2 m / 6 ft 6" with PowerCon TRU
   
Dimensions 56 x 35 x 23 cm / 2.2 x 1.3 x 0.9"
   
Weight ~14 kg / 30 lb 13 oz with batteries
~ 8 kg / 17 lb 10 oz without batteries

 

Class II sound level meter PCE-428-EKIT with octave filter (optional 1/3 octave filter) for frequency analysis / ICCP 40mV/PA microphone / Data logger / Weighting A, B, C, Z / Fast, slow, pulse analysis and peak analysis / MicroSD / USB cable / 3 measurement profiles / ISO calibration certificate

The PCE-428-EKIT sound level meter ensures detailed high-accuracy measurements with frequency weightings A, B, C, and Z as well as with the four sound measurement speeds Fast, Slow, Pulse, and Peak.

Additionally, the meter can store measurements in 3 different user profiles. Here the user can decide which parameters the sound level meter should record in each profile. For example, you can choose between Laeq, LcPeak, LaFmax, LaFMin and so on.

An innovative feature for the PCE-428-EKIT is the Peak function, which ensures recording of the maximum sound pressure level during a long-term measurement. A 24bit AD converter helps reduce the inherent noise to a very low level. The 48 kHz signal sampling rate allows high measurement accuracy.

PCE-4xx-EKIT

An additional kit for outdoor sound measurement PCE-4xx-EKIT can be combined with the sound level meters PCE-428, 430, or PCE-432. This kit makes it possible to measure outdoor noise with a sound level meter for a long period. The environmental noise monitoring system consists of a waterproof Peli transport case with rollers. A charger and two additional lead gel batteries have been placed in this case, which allow the sound meter to operate for up to 10 days. During outdoor sound measurement, the case can remain closed. Due to the external connections for the microphone and the power supply, all electronic components are protected from water.

The screen insulation provides protection from wind and rain, and the microphone windshield isolates the measurement from the effect of wind. The charger of the PCE-4xx-EKIT kit is waterproof and can remain outdoors. Also, a tripod is available with which the microphone can be placed outdoors. 

The PCE -4xx–EKIT can be used for noise measurement in critical areas such as road surfaces in residential areas, airports, depots, as well as for measuring acoustic events. 

- 1/1 octave (optionally 1/3 octave)

- Category Class 2

- Frequency weighting A, B, C & Z

- Fast, slow, pulse, and peak measurement speed (FAST, SLOW, PULSE, PEAK)

- Statistical function

- Display of sound profile as a graph

- 3 adjustable measurement profiles

- Low influence of inherent noise

- ICCP microphone 40 mV / PA

- Adjustable alarm level

 

Package contents

1 x External sound level meter PCE-428-EKIT (includes external noise level meter kit)

1 x 1/2" class II measurement microphone

1 x Microphone windscreen

1 x USB cable

1 x Software

1 x Power Supply

1 x Carrying case

1 x User manual

1 x External meter kit PCE-4xx-EKIT

1 x Waterproof PELI carrying case

1 x Wind and rain protection for the PCE-4xx series microphone

1 x Charger for internal batteries

2 x 12V batteries 

1 x tripod

1 x 2 m / 6ft microphone cable

1 x Connection cable for 110 V / 230 V power supply (optional Schuko or USB connection)

Note: The PCE-428-EKIT ambient sound level meter comes with an octave band filter. Optional upgrade with 1/3 octave band filter (see option)

 