HCHO
Measurement range 0.00 … 5.00 mg/m³
Reading 0.01 mg/m³
Accuracy ±5 % of the measuring range
TVOC
Measurement range 0.00 … 9.99 mg/m³
Reading 0.01 mg/m³
Accuracy ±5 % of the measuring range
Temperature
Measurement range 0 … 50 °C / 32 … 122 °F
Reading 0.1 °C / 0.1 °F
Accuracy ±2 °C / ±4 °F
Humidity
Measurement range 0 … 100 % RH
Reading 0.1% RH
Accuracy ±3.5 % at (20 … 80 % RH)
±5 % to (0 … 20 %)
±5 % to (80 … 100 %)
Further specifications
Memory for 5000 measurement points
File format CSV
Storage rate 1 minute, 15 minutes, 1 hour
Warm-up time HCHO: 10 seconds
TVOC: 90 seconds
Units temperature: °C, °F
HCHO / TVOC: ppm, mg/m3
Rate of measurement 1 Hz
Alarm optical
Exit Micro USB interface
Battery powered 3.7V, 1500mAh
Power supply with transformer 5V DC, 1A
Operating conditions 0 … 45 °C / 32 … 113 °F, <90 % RH
Storage conditions -10 … 55 °C / 14 … 131 °F, <90 % RH
Dimensions 54 x 215 x 34mm / 2.1 x 8.4 x 1.3"
Weight 143g / 5.0oz

Gas detector with data memory / Export of stored measurement data to CSV /
HCHO / TVOC / temperature / humidity / measuring range 0.00 ... 9.99 mg/m³ /
1500 mAh battery / portable and fixed use / Micro USB interface

The gas detector is equipped with various sensors to measure formaldehyde (HCHO), gaseous volatile organic compounds (TVOC), ambient temperature and humidity. This means that the air quality meter covers a wide range of tasks. With an accuracy of ±5% of the measuring range for HCHO and TVOC, the PCE-EM 880 is the ideal measuring instrument for safe and reliable measurements.

The device is powered by a 1500mAh battery, which can be recharged via micro USB with a 5V DC power supply.

Therefore, the gas detector is used, for example, to check the air quality in offices, laboratories, school premises or in warehouses to check the premises for volatile organic substances and formaldehyde.

Measurements are saved directly in CSV format in a memory of 5000 records and can be transferred to a computer for further analysis and processing. 

- Memory for 5000 measurement points
- Measuring range 0.00 ... 9.99 mg/m³ (TVOC)
- Easy operation with virtual keys
- Battery and power operation
- Tripod base for stable use
- Individually adjustable alarm limits
Package contents
1 x PCE-EM 880 Gas Detector
1 x Micro USB Cable
1 x User Manual