What a vibration meter measures
Every rotating machine vibrates. What we pick up on a bearing housing or casing is the outward result of the forces acting inside the machine. When a fault develops, such as unbalance, misalignment, looseness, or wear in bearings and gears, those forces change, and the vibration changes with them.
A vibration meter uses a sensor to turn this motion into an electrical signal and reports two kinds of information. The overall level tells you how strongly the machine is vibrating. On instruments with FFT analysis, the frequency spectrum helps you find out why. Taking readings at the same points on a regular schedule builds a trend, which shows when a machine starts to deteriorate so that maintenance can be planned before it fails.
Three ways to describe vibration
A single oscillation can be expressed in three ways. These are not three different vibrations, but three views of the same signal, linked to each other through frequency.
How far a point moves away from its rest position.
µm, usually Peak-to-Peak
How fast the point is moving, in other words the rate of change of displacement.
mm/s, usually RMS
How fast the velocity changes. It peaks at the ends of travel, where velocity drops to zero.
m/s² or g (1 g = 9.81 m/s²)
For a sinusoidal vibration at frequency f, differentiating displacement gives velocity, and differentiating velocity gives acceleration. Each step multiplies the amplitude by ω = 2πf. As a result, at high frequencies acceleration becomes large while displacement becomes very small.
v(t) = ωX · cos(ωt)
a(t) = −ω²X · sin(ωt)
ω = 2πf · X = displacement amplitude
The choice depends on frequency
Below roughly 10 Hz, displacement gives the most meaningful readings, for example on slow-running machines. Between 10 Hz and 1 kHz, velocity is the best indicator of vibration severity. Most general-purpose rotating machines run in this range and most of their faults show up there, which is why velocity is the most widely used parameter. Above 1 kHz, where bearing and gear defects appear, acceleration is the parameter of choice.
The 10 Hz to 1 kHz band used in severity standards also has a historical reason: the original data were collected with velocity pickups, which measure accurately over roughly that range.
RMS, Peak, Peak-to-Peak and Crest Factor
Once the parameter is chosen, we still have to decide how to express its amplitude. A vibration meter can report the same signal in four ways. The ratios in the “Sine wave” column hold only for a pure sinusoid. Real machine signals depart from them, and that difference is useful information in itself.
| Value | What it shows | Sine wave | Typical use |
|---|---|---|---|
| RMS | Effective value; reflects the energy content of the vibration | 0.707 × Peak | ISO severity assessment (velocity) |
| Peak | Highest instantaneous value measured from zero | 1.414 × RMS | Velocity and acceleration on IRD style charts |
| Peak-to-Peak | Total travel from one extreme to the other | 2 × Peak | Displacement in µm, e.g. shaft motion |
| Crest Factor | Ratio of Peak to RMS; how spiky the signal is | √2 ≈ 1.41 | Condition trending, impacts |
ISO adopted velocity RMS as the measure of vibration severity because it is tied to the energy of the vibration. Crest Factor complements it. When short impacts appear in a signal, its peaks rise far more than its RMS value, so the ratio climbs above the 1.41 of a clean sine wave. This makes Crest Factor a useful value for tracking a machine’s condition over time.
Assessing severity to ISO
The simplest use of a vibration meter is to compare the overall level with the limits in a standard. These limits trace back to the empirical charts of Rathbone and Yates. They were adopted in VDI 2056 (1957), then in ISO 2372 (1974), later in the ISO 10816 series, which has since been replaced by the ISO 20816 series. The approach has stayed the same: measure velocity RMS in mm/s, over 10 Hz to 1 kHz, on the non-rotating parts of the machine such as the bearing housings.
The standards rely on velocity because, for vibration in a given mode, velocity relates to the mechanical stress in the material regardless of machine size. The reading falls into one of four zones:
Good. Levels typical of newly commissioned machines.
Acceptable. The machine can run long term without restriction.
Just tolerable. Not suitable for continuous long-term operation; investigate and plan corrective action.
Not permissible. The vibration level is high enough to damage the machine.
Zone limits depend on the size of the machine and on its foundation. The table lists the values from ISO 10816-1 (Table B.1) for the four general classes. A reading belongs to a zone when it is less than or equal to that column’s limit.
| Class | Typical machines | A / B | B / C | C / D |
|---|---|---|---|---|
| Class I | Small machines and components, typically under 15 kW | 0.71 | 1.8 | 4.5 |
| Class II | Medium machines without special foundations, typically 15 to 75 kW | 1.12 | 2.8 | 7.1 |
| Class III | Large machines on rigid, heavy foundations | 1.8 | 4.5 | 11.2 |
| Class IV | Large machines on flexible foundations, e.g. turbomachines | 2.8 | 7.1 | 18 |
Values in mm/s velocity RMS. Industrial machines above 15 kW have their own part of the standard (now ISO 20816-3), with separate limits by machine group and type of support.
A 30 kW electric motor without a special foundation (Class II) reads 3.8 mm/s RMS. That is above 2.8 and below 7.1, so the machine is in zone C.
The trend matters more than the absolute value
There is no vibration level above which a machine breaks down on the spot. Two identical machines can run trouble-free for years at very different levels, and machines in the same class can differ widely in how their structure responds. The ISO zones are a useful guide, not a criterion for shutting a machine down.
A more reliable approach is to watch for change in the level at the same point, under the same load and speed. An increase by a factor of 2 to 2.5 is significant; an increase by a factor of 10 is serious. A rising trend deserves attention even while the reading is still in zone A or B.
Frequency analysis: FFT
The overall level tells you how much a machine vibrates, not why. The measured signal is the sum of many sinusoidal components, each at its own frequency. The Fourier transform breaks the time waveform down into these components and produces the spectrum: amplitude plotted against frequency. The FFT (Fast Fourier Transform) is the efficient algorithm digital instruments use to carry out this calculation on a sampled signal.
Because each mechanical fault produces vibration at characteristic frequencies, usually multiples of shaft speed, the spectrum points to the likely cause. Inside the instrument the signal passes through these stages:
Tap a setting to see what it affects.
fsSampling and aliasing›
The FFT works on samples of the signal. Under the Nyquist theorem, the sampling rate must be at least twice the highest frequency of interest. Any component above half the sampling rate shows up in the spectrum as a false, lower frequency. This is called aliasing.
Aliasing cannot be removed after the fact. Instruments therefore place an analog low-pass filter (anti-aliasing filter) ahead of the A/D converter, and retune it automatically whenever the frequency range is changed.
ΔfF-max, lines and resolution›
F-max is the highest frequency shown in the spectrum, and the number of lines (or bins, e.g. 400, 800, 1600, 3200) is how many points divide it. The spacing between lines is Δf = F-max / lines. For example, 1000 Hz with 400 lines gives 2.5 Hz per line. A smaller Δf separates closely spaced peaks better, but each measurement takes longer.
As a guideline, set F-max to about 20 to 40 times running speed for pumps, fans and motors, and to at least three times the gear mesh frequency (GMF) for gearboxes. When measuring a machine for the first time, take one spectrum at 10 times and another at 100 times running speed so that nothing is missed.
WWindows: Rectangular, Hanning, Flat top›
The FFT processes a finite slice of signal. If that slice does not hold a whole number of cycles, a discontinuity forms at its edges and the energy of one frequency spreads into neighbouring lines. This is leakage. A window multiplies the signal by a function that tapers it smoothly to zero at both ends.
Hanning is the usual default for continuous machine signals. Flat top gives the most accurate peak amplitude at the cost of wider peaks, and is preferred for calibration. Rectangular (no window) suits short transient signals such as hammer impact tests, or cases where sampling is synchronised with shaft speed.
AvgAveraging and overlap›
A single spectrum is affected by random noise. Linear averaging combines several spectra (typically 4 to 32) so that the result is repeatable. Peak hold keeps the highest value seen on each line and is used for transients such as a machine coasting down. Synchronous time averaging uses a once-per-revolution reference pulse from the shaft and keeps only what is locked to shaft rotation.
With overlap (e.g. 50% or 75%), each new spectrum reuses part of the previous block of data, so averages complete much faster. This matters most at low frequencies.
Reading the spectrum
Frequencies are usually expressed as orders of shaft speed: 1× is the rotational frequency, 2× is twice that, and so on. The table summarises the most common fault signatures. A firm diagnosis combines the spectrum with measurement direction, phase and experience.
| Fault | Frequencies | Signs |
|---|---|---|
| Unbalance | 1× | Dominant peak at 1×; amplitude grows with the square of speed |
| Misalignment | 1×, 2×, 3× | High axial vibration; about 180° phase difference across the coupling |
| Bent shaft | 1×, 2× | High vibration both radially and axially |
| Looseness | many ×, ½× | A series of harmonics, often with subharmonics; unstable phase, strongly directional |
| Rolling bearings | BPFO, BPFI, BSF, FTF | Higher frequencies that are not whole multiples of shaft speed; set by bearing geometry |
| Gears | GMF ± 1× | GMF = number of teeth × shaft speed; sidebands spaced at the shaft speed |
Bearing wear develops in stages. The first signs appear at very high frequencies, well before the defect frequencies become visible in a normal spectrum. That is why many instruments offer dedicated bearing functions such as envelope analysis (demodulation), which pull repetitive impacts out of the machine’s general vibration.
Sensors and mounting
No single sensor covers every need. The three main types are:
| Sensor | Principle | Typical range | Best for |
|---|---|---|---|
| Accelerometer | Piezoelectric crystal loaded by a mass; output proportional to acceleration | 1…10,000 Hz | General use, bearings, gears |
| Velocity pickup | Coil and magnet; needs no power supply | 10…1000 Hz | Mid frequencies, general monitoring |
| Proximity probe | Eddy current; measures the gap between probe and shaft | from 0 Hz | Relative shaft motion in journal bearings, turbomachinery |
An accelerometer with electronic integration of its signal provides velocity and displacement as well, over a wider frequency range than a velocity pickup. How the sensor is attached limits the highest frequency it can measure correctly, because every intermediate part adds a resonance below that of the sensor itself:
Stud mounting: the sensor’s full rated range; the best option for permanent installation, on a clean, flat surface.
Adhesive: secure attachment without machining, with some loss at high frequencies.
Magnet: the usual choice for route-based readings with a portable instrument; a narrower usable range than a stud.
Handheld probe: quick, but with the narrowest usable frequency range.
Each sensor measures only along its own axis. Since vibration differs by direction, measure every bearing vertically, horizontally and axially, always at the same points, so that readings can be compared over time.
Other applications
Beyond machine condition, vibration measurement is also used to assess worker exposure. Whole-body vibration (for example, drivers of vehicles and mobile machinery) is evaluated to ISO 2631, and hand-arm vibration from hand-held tools to ISO 5349-1 and ISO 5349-2.
In buildings, vibration from road traffic, railways, construction sites or building services (lifts, HVAC) is commonly assessed to DIN 4150.
What to look for when choosing
Parameters and frequency range: at least velocity over 10 Hz to 1 kHz for ISO assessment; acceleration over a wider range for bearings and gears.
Built-in ISO evaluation: the instrument shows zone A, B, C or D directly for the selected machine class.
FFT: essential if you need to find the cause, not just confirm that vibration has gone up. Check F-max and the number of lines.
Bearing functions: Crest Factor, envelope, or a comparable bearing condition indicator.
Memory and software: to store readings per measuring point and follow the trend over time. Some instruments also measure speed or surface temperature.
Vibration Meters
PCE-VT 1100
Vibration Meter for Machine Inspection and Maintenance